Daikin EHVH08SU26CB6W [3/108] General safety precautions

Daikin EHVH08SU26CB6W [3/108] General safety precautions
1 General safety precautions
Installer reference guide
3
ERLQ004~008CA + EHVH04+08SU18+26CB6W
Daikin Altherma – Low temperature split
4P449978-1 – 2016.06
7.8.6 To fill the water circuit ................................................. 41
7.8.7 To fill the domestic hot water tank .............................. 41
7.8.8 To insulate the water piping ........................................ 41
7.9 Connecting the electrical wiring................................................. 41
7.9.1 About connecting the electrical wiring......................... 41
7.9.2 About electrical compliance ........................................ 41
7.9.3 Precautions when connecting the electrical wiring ..... 42
7.9.4 Guidelines when connecting the electrical wiring ....... 42
7.9.5 To connect the electrical wiring on the outdoor unit.... 42
7.9.6 To connect the electrical wiring on the indoor unit...... 42
7.9.7 To connect the main power supply ............................. 43
7.9.8 To connect the backup heater power supply .............. 44
7.9.9 To connect the user interface ..................................... 45
7.9.10 To connect the shut-off valve...................................... 46
7.9.11 To connect the electrical meters ................................. 46
7.9.12 To connect the domestic hot water pump ................... 46
7.9.13 To connect the alarm output ....................................... 46
7.9.14 To connect the space heating ON/OFF output ........... 46
7.9.15 To connect the changeover to external heat source... 47
7.9.16 To connect the power consumption digital inputs ....... 47
7.9.17 To connect the safety thermostat (normal closed
contact) ....................................................................... 47
7.9.18 To connect the booster heater power supply.............. 47
7.10 Finishing the outdoor unit installation ........................................ 48
7.10.1 To finish the outdoor unit installation .......................... 48
7.10.2 To close the outdoor unit ............................................ 48
7.11 Finishing the indoor unit installation .......................................... 48
7.11.1 To fix the user interface cover to the indoor unit......... 48
7.11.2 To close the indoor unit............................................... 48
8 Configuration 48
8.1 Overview: Configuration ............................................................ 48
8.1.1 To connect the PC cable to the switch box................. 48
8.1.2 To access the most used commands ......................... 49
8.1.3 To copy the system settings from the first to the
second user interface.................................................. 49
8.1.4 To copy the language set from the first to the second
user interface .............................................................. 50
8.1.5 Quick wizard: Set the system layout after first power
ON............................................................................... 50
8.2 Basic configuration .................................................................... 50
8.2.1 Quick wizard: Language / time and date..................... 50
8.2.2 Quick wizard: Standard............................................... 51
8.2.3 Quick wizard: Options ................................................. 52
8.2.4 Quick wizard: Capacities (energy metering) ............... 55
8.2.5 Space heating control ................................................. 55
8.2.6 Domestic hot water control ......................................... 58
8.2.7 Contact/helpdesk number ........................................... 58
8.3 Advanced configuration/optimization......................................... 58
8.3.1 Space heating operation: advanced ........................... 58
8.3.2 Domestic hot water control: advanced........................ 61
8.3.3 Heat source settings ................................................... 66
8.3.4 System settings........................................................... 68
8.4 Menu structure: Overview user settings .................................... 72
8.5 Menu structure: Overview installer settings............................... 73
9 Commissioning 74
9.1 Overview: Commissioning ......................................................... 74
9.2 Precautions when commissioning ............................................. 74
9.3 Checklist before commissioning ................................................ 74
9.4 Checklist during commissioning ................................................ 74
9.4.1 To check the minimum flow rate ................................. 75
9.4.2 Air purge function........................................................ 75
9.4.3 To perform a test run .................................................. 76
9.4.4 To perform an actuator test run .................................. 76
9.4.5 Underfloor heating screed dryout................................ 76
10 Hand-over to the user 78
11 Maintenance and service 78
11.1 Overview: Maintenance and service ......................................... 78
11.2 Maintenance safety precautions................................................. 78
11.2.1 Opening the indoor unit................................................ 78
11.3 Checklist for yearly maintenance of the outdoor unit ................. 78
11.4 Checklist for yearly maintenance of the indoor unit.................... 78
11.4.1 To drain the domestic hot water tank........................... 79
12 Troubleshooting 80
12.1 Overview: Troubleshooting......................................................... 80
12.2 Precautions when troubleshooting ............................................. 80
12.3 Solving problems based on symptoms....................................... 80
12.3.1 Symptom: The unit is NOT heating as expected ......... 80
12.3.2 Symptom: The compressor does NOT start (space
heating or domestic water heating).............................. 80
12.3.3 Symptom: The pump is making noise (cavitation) ....... 81
12.3.4 Symptom: The pressure relief valve opens.................. 81
12.3.5 Symptom: The water pressure relief valve leaks ......... 81
12.3.6 Symptom: The space is NOT sufficiently heated at
low outdoor temperatures ............................................ 81
12.3.7 Symptom: The pressure at the tapping point is
temporarily unusually high ........................................... 81
12.3.8 Symptom: Decoration panels are pushed away due
to a swollen tank .......................................................... 82
12.3.9 Symptom: Tank disinfection function is NOT
completed correctly (AH-error)..................................... 82
12.3.10 Symptom: There is NO water flow from the hot taps ... 82
12.3.11 Symptom: The water from the hot taps is cold............. 82
12.3.12 Symptom: The water discharge is intermittent............. 82
12.3.13 Symptom: The water flow from the taps does not
stop .............................................................................. 82
12.4 Solving problems based on error codes ..................................... 82
12.4.1 Error codes: Overview ................................................. 82
13 Disposal 85
13.1 Overview: Disposal..................................................................... 85
13.2 To pump down............................................................................ 85
13.3 To start and stop forced cooling ................................................. 85
14 Technical data 86
14.1 Components and dimensions: Indoor unit.................................. 86
14.2 Piping diagram: Outdoor unit...................................................... 88
14.3 Piping diagram: Indoor unit ........................................................ 89
14.4 Wiring diagram: Outdoor unit ..................................................... 90
14.5 Wiring diagram: Indoor unit ........................................................ 91
14.6 Technical specifications: Indoor unit .......................................... 94
14.7 ESP curve: Indoor unit ............................................................... 95
15 Glossary 96
16 Field settings table 97
1 General safety precautions
1.1 About the documentation
The original documentation is written in English. All other
languages are translations.
The precautions described in this document cover very important
topics, follow them carefully.
The installation of the system, and all activities described in the
installation manual and the installer reference guide must be
performed by an authorized installer.
1.1.1 Meaning of warnings and symbols
DANGER
Indicates a situation that results in death or serious injury.

Содержание

Похожие устройства

Скачать