Daikin EHSXB08P30A — основные компоненты и настройки теплового насоса [53/68]

Daikin EHSH08P50A [53/68] Pump continuous running off
Fig. 7-4 Components in the heat pump circuit (simplified diagram)
a Plate heat exchanger (condensator)
b Ventilator motor
c Lamella heat exchanger (evaporator)
eFilter
f Electronic expansion valve
g Service valve (liquid line)
h Service valve with mainte
nance connection (gas line)
i Accumulator
k Coolant compressor
n 4-way diverter valve (—> Heat, ·
···> Cool)
o Inverter board
R1T External temperature sensor
R2T Discharge temperature sensor (coolant compressor)
R3T* Suction temperature sensor (coolant compressor)
R4T* Temperature sensor lamella heat exchanger-input
R5T Temperature sensor lamella heat exchanger-middle
R6T* Temperature sensor liquid line (t
L2
)
R10T* Temperature sensor on inverter board
S1PH High pressure switch
S1NPH Pressure sensor
* Only with 11-16 kW heat pump external devices.
Tab. 7-3 Legend for fig. 7-4
7 x Errors, malfunctions and messages
Daikin Altherma EHS(X/H)
Daikin Solar tank with integrated interior heat pump unit
008.1420744 – 06/2015
Installation and maintenance manual
53
7.4 Monitoring and configuration DIP Switch
WARNING!
Touching live parts can result in an ele
ctric shock
and lead to potentially fatal injuries and burns.
Before beginning work on live parts, disconnect
all of the systems circuits from the power supply
(switch off main switch, disconnect fuse) and
secure against unintentional restart.
Disconnect the
system from the power supply.
Ope
n the control housing and remove the RoCon BM1 board
(see chapter 3.4.9).
Check th
e DIP switch setting on the A1P circuit board of the
Daikin Altherma EHS(X/H), adjust where necessary
(see tab. 7-4).
The factory preset may only be changed if e.g. an
op
tional accessory was connected.
Repl
ace the RoCon BM1 switch board, close the control
housing and reconnect the power supply.
DIP switch settings are not recognised until a brief inter-
ruption to the power supply.
Fig. 7-5 Setting of DIP switch SS2
DIP
switch
No. Designation Factory setting
SS2
1 Do not change. OFF
2
Domestic hot water gener-
ation
ON
3 Pump continuous running* OFF
4 Do not change. OFF
* If you intend to run the internal heating circulation pump continuously, it will
need to be connected to the circuit board A1P, plug X17A, via a separate con-
nection cable (
E1400132).
Tab. 7-4 DIP switch settings