Tecnoclima VX 1000 [71/116] Overall dimensions

Tecnoclima VX 1000 [71/116] Overall dimensions
68
69
PA SERiES SiNGLE-STAGE - PA-2 SERiES DOUBLE-STAGE - PA-4 SERiES Bi-POWER
Models
Unit
PA 16 PA 26 PA 36 PA 46 PA 66 PA 86 PA 106
Heating capacity input
kW 15 25,4 33,8 46,3 65 85 104,7
kcal/h 12.900 21.844 29.068 39.818 55.900 73.100 90.042
Max. USEFUL heating capacity output
(single-stage)
kW 13,8 23 30,5 41,7 58,6 76,6 94,3
kcal/h 11.868 19.780 26.230 35.862 50.396 65.876 81.098
Min. USEFUL heating capacity output
(Double-stage - Bi-power)
kW 8,7 15,8 21 28,8 40,5 52,9 65,2
kcal/h 7.482 13.588 18.060 24.768 34.830 45.494 56.062
Max. air flow rate Nm
3
/h 1.250 1.820 2.920 4.130 5.900 7.900 8.750
Min. air flow rate (Bi-power)
Nm
3
/h 1.000 1.750 2.600 3.700 5.000 7.200 7.800
Temperature deviation max. °K 32 37 31 30 30 29 32
Temperature deviation min. °K 26 26 24 23 24 22 25
Electrical supply V - 50Hz 230 ~ 230 ~ 230 ~ 230 ~ 230 ~ 230 ~ 230 ~
OVERALL DIMENSIONS
Models
Dimensions mm
Chimney
Ø mm
Burner air
inlet Ø mm
Weight Kg
A B C
PA 16 610 560 860 100 100 65
PA 26 665 560 860 100 100 75
PA 36 745 560 860 100 100 80
PA 46 925 560 860 100 100 95
PA 66 1.170 560 860 100 150 132
PA 86 1.720 560 860 100 150 180
PA 106 1.960 560 860 100 150 220
A
B
C
Thermal Performance GASTEC certified
TECHNICAL SPECIFICATIONS SERIES
PA

Содержание

Скачать