Daikin EKHWP300B [22/28] Basic data
![Daikin EKHWP300B [22/28] Basic data](/views2/1788417/page22/bg16.png)
Installation and maintenance manual
22
Daikin EKHWP300+500
Daikin High-performance hot water storage tank
008.1618744 – 08/2015
8 x Technical data
8 Technical data
Not all the hot water storage tanks listed here are
offered certain countries.
8.1 Basic data
Unpressurised (DrainBack) - DB
Unit EKHWP300B EKHWP500B
Energy labelling Regulation: (EU) 811/2013 / Ecodesign Regulation: (EU) 813/2013
Energy efficiency class — B
Standing loss W 64 72
Hot water storage tank volume litres 294
477
Basic data
Empty weight kg 58 82
Total filled weight kg 359 593
Dimensions (L x W x H) without switching unit from E-PAC cm 59.5 x 61.5 x 164.6 79 x 79 x 165.8
Tilt dimension cm 163 167
Maximum permissible storag
e water temperature °C 85
Heat consumption at stand-by and at 60 °C kWh/24h 1.3 1.4
Drinking water heat exchanger (stainless steel 1.4404)
Potable water capacity litres 27.9
Maximum operating pressure bar 6
Domestic water heat exchanger surface m
2
5.8 6.0
Storage tank charging heat exchanger (stainless steel 1.4404)
Water capacity heat exchanger litres 13.2 18.5
Heat exchanger surface area m
2
2.7 3.8
Solar heating backup (stainless steel 1.4404)
Water capacity heat exchanger litres — 2.3
Heat exchanger surface area m
2
— 0.5
Thermal output data
Volume of hot water without reheating at draw-off rate
(8 l/
3)
/12 l/min
4)
) (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 50 °C)
litres 184
3)
/ 153
4)
364
3)7)
/ 318
4)7)
328
3)8)
/ 276
4)8)
Volume of hot water without reheating at draw-off rate
(8 l/
4)
/12 l/min
4)
) (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 60 °C)
litres 282
3)
/ 252
4)
540
3)
/ 494
4)
Volume of hot water without reheating at draw-off rate
(8 l/
4)
/12 l/min
4)
) (T
KW
= 10 °C/T
WW
= 40 °C/T
SP
= 65 °C)
litres 352
3)
/ 321
4)
612
3)
/ 564
4)
Reheating time (Wh) with a draw-off quantity
(bathtub: 140 l
5)
/ shower: 90 l
6)
)
(T
KW
=10 °C / T
WW
=40 °C / T
SP
=50 °C)
min 45
5)9)
/ 30
6)9)
25
5)10)
/ 17
6)10)
Pipe connections
Cold and hot water inches 1" AG
Heating flow / Return flow inches 1" IG / 1" AG
Solar connections inches 1" IG
Tab. 8-1 Basic data EKHWP - Drain-Back
7) Charging by heat pump and electric booster heater.
8) Charging only by heat pump without
electric booster heater.
9) With heat pump 8 kW.
10) With heat pump 16 kW.
Содержание
- High performance hot water storage tank 1
- Installation and maintenance manual 1
- Annual inspection 1 3
- Avoid danger 3
- Basic data 22 3
- Brief description 0 3
- Connection diagrams 9 3
- Design and components 3
- Draining the storage tank 7 3
- Filling topping up 4 3
- Final shutdown 8 3
- Hydraulic connection 19 3
- Installation 3 3
- Instructions for operating safety 3
- List of contents 3
- List of keywords 27 3
- Notes 25 3
- Observing instructions 3
- Optional accessories 1 3
- Performance diagrams 24 3
- Periodic checks 1 3
- Product description 7 3
- Proper use 3
- Safety 4 3
- Scope of delivery 0 3
- Service and maintenance 21 3
- Set up 2 3
- Set up and installation 12 3
- Start up 16 3
- Taking out of service 17 3
- Technical data 22 3
- Temporary shutdown 7 3
- Tightening torque 24 3
- Warning signs and explanation of symbols 3
- Avoid danger 4
- Handling instructions 4
- Meaning of the warnings 4
- Observing instructions 4
- Relevant documents 4
- Safety 4
- Special warning signs 4
- Validity 4
- Warning signs and explanation of symbols 4
- X safety 4
- Before working on the hot water storage tank and the heating system 5
- Electrical installation of optional accessories 5
- Heating and sanitary side connection 5
- Installation room 5
- Instructions for operating safety 5
- Operation 5
- Proper use 5
- Requirements of the heating and filling water 5
- X safety 5
- Documentation 6
- Instructing the user owner 6
- X safety 6
- Design and components 7
- Product description 7
- X product description 7
- Fig 2 1 connections and dimensions high performance hot water storage tank with solar support type ekhwp 300 500b 8
- High performance hot water storage tank for heat pump systems 8
- Unpressurised system drainback 8
- X product description 8
- Fig 2 2 connections and dimensions high performance hot water storage tank with solar support type ekhwp 300 500bp 9
- Pressurised system 9
- X product description 9
- Brief description 10
- Economical operation 10
- Electronic control 10
- Low maintenance and corrosion 10
- Low scaling 10
- Modular extension facility 10
- Optimum water hygiene 10
- Scope of delivery 10
- X product description 10
- Dirt filter 11
- Electric immersion heaters 11
- For ekhwp booster heater 11
- Kfe filling connection 11
- Non return valves 11
- Optional accessories 11
- Scalding protection 11
- Solar storage tank extension kit 11
- X product description 11
- Important information 12
- Installing the hot water storage tank 12
- Set up 12
- Set up and installation 12
- X set up and installation 12
- Hydraulic system connection 13
- Important information 13
- Installation 13
- X set up and installation 13
- Buffer tank 14
- Ekhwp hot water storage tank without solar system and without kfe filling connection kfe ba 14
- Filling topping up 14
- Hot water heat exchanger 14
- X set up and installation 14
- Ekhwp hot water storage tank with solar system 15
- X set up and installation 15
- Start up 16
- X start up 16
- Draining the storage tank 17
- Taking out of service 17
- Temporary shutdown 17
- With pre mounted kfe filling connection 17
- With solar system 17
- With subsequently fitted kfe filling connection 17
- Without kfe filling connection 17
- Without solar system 17
- X taking out of service 17
- Draining the heating circuit and hot water circuit 18
- Final shutdown 18
- Recommendations for disposal 18
- X taking out of service 18
- Connection diagrams 19
- Hydraulic connection 19
- Solution for low temperature heat pumps 19
- X hydraulic connection 19
- X hydraulic connection 20
- Annual inspection 21
- Periodic checks 21
- Service and maintenance 21
- X service and maintenance 21
- Basic data 22
- Technical data 22
- Unpressurised drainback db 22
- X technical data 22
- Pressurised system p 23
- X technical data 23
- Booster heater 1 max 10 nm hand tight 24
- Cabling on terminal rail k1 ehs all 0 1 nm 24
- Cover flap fixing screws ehs 4 x 19 1 nm 24
- Designation thread size tightening torque 24
- Hydraulic line connections water 1 25 to 30 nm 24
- L min can in certain rare circum stances lead to noises in the domestic water heat exchanger of the hot water storage tank 24
- Performance diagrams 24
- Tension release ehs m20 6 nm 24
- Tightening torque 24
- X technical data 24
- X notes 25
- X notes 26
- List of keywords 27
- Numerics 27
- X list of keywords 27
Похожие устройства
- Daikin EKHWP54419BA Схема
- Daikin EKHWP54419BA Инструкция по эксплуатации
- Daikin EKHWP54419BA Руководство по эксплуатации
- Daikin EKHWP500B Схема
- Daikin EKHWP500B Инструкция по эксплуатации
- Daikin EKHWP500B Руководство по эксплуатации
- Daikin EKHWP300PB Схема
- Daikin EKHWP300PB Инструкция по эксплуатации
- Daikin EKHWP300PB Руководство по эксплуатации
- Daikin EKHWP500PB Схема
- Daikin EKHWP500PB Инструкция по эксплуатации
- Daikin EKHWP500PB Руководство по эксплуатации
- Daikin EKHWCH300PBA Схема
- Daikin EKHWCH300PBA Инструкция по эксплуатации
- Daikin EKHWCH500PBA Схема
- Daikin EKHWCH500PBA Инструкция по эксплуатации
- Daikin EKHWP300A Инструкция по эксплуатации
- Daikin EKHWP500A Инструкция по эксплуатации
- Foodatlas KCB-1F (световой короб, стол для топпингов) Инструкция по эксплуатации
- Foodatlas KCB-1F (световой короб, стол для топпингов) Сертификат