Daikin EKCBH008BCV3 [8/24] Quiet mode operation s
![Daikin EKCBX008BCV3 [8/24] Quiet mode operation s](/views2/1789211/page8/bg8.png)
Operation manual
7
EKCBX/H008BCV3
Unit for air to water heat pump system
4P348534-1 – 2013.04
Quiet mode operation (s)
Quiet mode operation means that the outdoor unit works at reduced
capacity so that the sound produced by the outdoor unit drops. This
implies that the indoor heating (and cooling) capacity will also drop.
Beware of this when a certain level of heating (or cooling) is required
indoors.
4.6. Controller operations
Manual operation
In manual operation, the user manually controls the settings of the
installation. The last setting remains active until the user changes it or
until the schedule timer forces another setting (refer to "Schedule
timer operation" on page 8).
As the controller can be used for a wide variety of installations, it is
possible to select a function which is not available on your
installation. In that case the message n will appear.
Switching on and setting space heating (h) and space cooling
(c)
1 Use the = button to select space heating (h) or space cooling
(
c).
Icon h or c appears on the display as well as the corresponding
water temperature set point.
2 Use the bi and bj buttons to set the desired water
temperature.
•Temperature range for heating: 25°C to 55°C
The temperature for heating can be set as low as 15°C (see
"Field settings" on page 13). However, the temperature for
heating should only be set lower than 25°C during
commissioning of the installation. When set lower than 25°C,
only the backup heater will operate (in case EKMBUHBA6V3
is installed).
In order to avoid overheating, space heating is not operable
when the outdoor ambient temperature rises above a certain
temperature (as set through field setting [4-02], refer to "Field
settings" on page 13).
•Temperature range for cooling: 5°C to 22°C
3 Switch on the unit by pushing the
y button.
The operation LED
0 lights up.
Selection and setting of domestic water heating (
w)
1 Use the v button to activate domestic water heating (w).
Icon w appears on the display.
2 Use the wi or wj button to display the actual
temperature set point and subsequently, to set the correct
temperature.
The actual temperature set point only appears on the display
after pressing one of the buttons wi or wj. If no button is
pressed for 5 seconds, the temperature set point will
automatically disappear from the display again.
Temperature range for domestic water heating: 30°C to 78°C
3 Press the
v button to deactivate domestic water heating (w).
Icon w disappears from the display.
Selecting powerful domestic water heating operation
1 Press v for 5 seconds to activate powerful domestic water
heating operation.
Icons w and m start flashing.
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (s)
1 Use the s button to activate quiet mode operation (s).
Icon s appears on the display.
If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 13), the s button will not be operable.
Selecting weather dependent set point operation (only in
heating mode)
1 Press the ba button to select weather dependent set point
operation.
Icon a appears on the display as well as the calculated water
temperature set point based on the outdoor temperature.
2 Use the bi or bj button to display the actual shift value
and subsequently, to set the correct value.
The shift value only appears on the display after pressing one of
the buttons bi or bj. If no button is pressed for 5
seconds, the shift value will automatically disappear from the
display again.
Range for the shift value: –5°C to +5°C
CAUTION
The actual operation range depends on the values set on
field setting [9].
These values shall be determined based on the
application.
INFORMATION
In heating mode (h) or in cooling mode (c), the water
temperature set point can also be weather dependent (icon
a is shown).
This means that the controller calculates the water
temperature set point based on the outdoor temperature.
In this case the controller shows the calculated controller
set point. The bi button or bj button can be used to
display the actual "shift value" and subsequently, to set the
correct value. This shift value is the temperature difference
between the temperature set point calculated by the
controller and the real set point. E.g. a positive shift value
means that the real temperature set point will be higher
than the calculated set point.
INFORMATION
When the unit is connected to an external room
thermostat, buttons = and y are not operable and the
icon
e is shown. In this case, the external room
thermostat switches the unit on or off and determines the
operation mode (space heating or space cooling).
INFORMATION
The domestic hot water set point set on the controller
is the actual domestic hot water set point ([4-03]=0, 1,
2, or 3) or the domestic hot water storage set point
([4-03]=4). See "Domestic water heating operation
(w)" on page 6.
INFORMATION
Remark that pushing the y button has no influence on
the domestic water heating. Domestic water heating is only
switched on or off by means of the v button.
Содержание
- Operation manual 1
- Unit for air to water heat pump system 1
- Definitions 2
- Efinitions 2
- Meaning of used terms 2
- Meaning of warnings and symbols 2
- Operation manual 2
- Afety precautions 3
- General safety precautions 3
- Introduction 3
- Ntroduction 3
- This manual 3
- This unit 3
- Features and functions 4
- Introduction 4
- Operating the digital controller 4
- Operating the unit 4
- Perating the unit 4
- Name and function of buttons and icons 5
- Setting the clock 6
- Setting the schedule timer 6
- Setting up the controller 6
- Description of the operation modes 7
- Domestic water heating operation 7
- Domestic water heating operation w 7
- Powerful domestic water heating operation 7
- Space cooling operation 7
- Space cooling operation c 7
- Space heating operation 7
- Space heating operation h 7
- Controller operations 8
- Manual operation 8
- Quiet mode operation 8
- Quiet mode operation s 8
- Schedule timer operation 9
- Getting started 10
- Programming and consulting the schedule timer 10
- Programming 11
- Consulting programmed actions 13
- Tips and tricks 13
- Field settings 14
- Ield settings 14
- Procedure 14
- Detailed description 15
- Field settings table 19
- Aintenance 21
- Disposal requirements 21
- Important information regarding the refrigerant used 21
- Isposal requirements 21
- Maintenance 21
- Maintenance activities 21
- Roubleshooting 21
- Standstill 21
- Troubleshooting 21
Похожие устройства
- Daikin EKCBH008BCV3 Инструкция по монтажу
- Daikin BEVN32AV1 Инструкция по монтажу
- Daikin BEVN50AV1 Инструкция по монтажу
- Daikin BEVN125AV1 Инструкция по монтажу
- Daikin BRC1E53A7 Инструкция по монтажу
- Daikin BRC1E53A7 Руководство по применению для установщика
- Daikin BRC1E53A7 Руководство по применению для пользователя
- Daikin BRC1E53B Инструкция по монтажу
- Daikin BRC1E53B Руководство по применению для установщика
- Garmin echo 200 Инструкция по эксплуатации
- Garmin echo 200 Инструкция по установке
- Samsung VP-DC575Wi Инструкция по эксплуатации
- Samsung VP-DC575WB Инструкция по эксплуатации
- Samsung VP-DC565WB(i) Инструкция по эксплуатации
- Samsung VP-DC565W(i) Инструкция по эксплуатации
- Samsung VP-DC563(i) Инструкция по эксплуатации
- Samsung VP-DC175WB Инструкция по эксплуатации
- Samsung VP-DC175W(i) Инструкция по эксплуатации
- Samsung VP-DC173(i) Инструкция по эксплуатации
- Samsung VP-DC172W Инструкция по эксплуатации