EKCBX/H008BCV3
Unit for air to water heat pump system
4P348534-1 – 2013.04
Operation manual
14
Detailed description
[0] User permission level
If required, certain user interface buttons can be made unavailable for
the user.
Three permission levels are defined (see the table below). Switching
between level 1 and level 2/3 is done by simultaneously pressing
buttons pfi and pfj immediately followed by
simultaneously pressing buttons s and ba, and keeping all 4
buttons pressed for at least 5 seconds (in normal mode). Note that no
indication on the user interface is given. When level 2/3 is selected,
the actual permission level – either level 2 or level 3 – is determined
by the field setting [0-00].
[1] Weather dependent set point
The weather dependent set point field settings define the parameters
for the weather dependent operation of the unit. When weather
dependent operation is active the water temperature is determined
automatically depending on the outdoor temperature: low outdoor
temperatures will result in warmer water and vice versa. During
weather dependent operation, the user has the possibility to shift up
or down the target water temperature by a maximum of 5°C.
■ Field settings for heating operation
■ [1-00] Low ambient temperature (Lo_A): low outdoor
temperature.
■ [1-01] High ambient temperature (Hi_A): high outdoor
temperature.
■ [1-02] Set point at low ambient temperature (Lo_Ti): the
target outgoing water temperature when the outdoor
temperature equals or drops below the low ambient
temperature (Lo_A).
Note that the Lo_Ti value should be higher than Hi_Ti, as for
low outdoor temperatures (i.e. Lo_A) warmer water is
required.
■ [1-03] Set point at high ambient temperature (Hi_Ti): the
target outgoing water temperature when the outdoor
temperature equals or rises above the high ambient
temperature (Hi_A).
Note that the Hi_Ti value should be lower than Lo_Ti, as for
warmer outdoor temperatures (i.e. Hi_A) less warm water
suffices.
■ Field settings for cooling operation
■ [1-05] Weather dependent for cooling function enable (1)/
disable (0)
■ [1-06] Low ambient temperature (Lo2_A): low outdoor
temperature.
■ [1-07] High ambient temperature (Hi2_A): high outdoor
temperature.
■ [1-08] Set point at low ambient temperature (Lo2_Ti): the
target outgoing water temperature when the outdoor
temperature equals or drops below the low ambient
temperature (Lo2_A).
Note that the Lo2_Ti value should be higher than Hi2_Ti, as
for low outdoor temperatures (i.e. Lo2_A) less cold water
suffices.
■ [1-09] Set point at high ambient temperature (Hi2_Ti): the
target outgoing water temperature when the outdoor
temperature equals or rises above the high ambient
temperature (Hi2_A).
Note that the Hi2_Ti value should be lower than Lo2_Ti, as
for warmer outdoor temperatures (i.e. Hi2_A) colder water is
required.
T
t
Target water temperature
T
A
Ambient (outdoor) temperature
Shift value Shift value
Button
Permission level
1 2 3
Quiet mode button s operable — —
Weather dependent
set point button
ba operable — —
Schedule timer
enable/disable button
pr operable operable —
Programming button < operable — —
Time adjust buttons
pfi
pfj
operable — —
Inspection/test
operation button
z operable — —
Lo_Ti
Lo2_Ti
Lo_A
Lo2_A
Hi_A
Hi2_A
T
A
T
t
+ 05
00
– 05
Hi_Ti
Hi2_Ti
Shift value
Содержание
- Operation manual 1
- Unit for air to water heat pump system 1
- Definitions 2
- Efinitions 2
- Meaning of used terms 2
- Meaning of warnings and symbols 2
- Operation manual 2
- Afety precautions 3
- General safety precautions 3
- Introduction 3
- Ntroduction 3
- This manual 3
- This unit 3
- Features and functions 4
- Introduction 4
- Operating the digital controller 4
- Operating the unit 4
- Perating the unit 4
- Name and function of buttons and icons 5
- Setting the clock 6
- Setting the schedule timer 6
- Setting up the controller 6
- Description of the operation modes 7
- Domestic water heating operation 7
- Domestic water heating operation w 7
- Powerful domestic water heating operation 7
- Space cooling operation 7
- Space cooling operation c 7
- Space heating operation 7
- Space heating operation h 7
- Controller operations 8
- Manual operation 8
- Quiet mode operation 8
- Quiet mode operation s 8
- Schedule timer operation 9
- Getting started 10
- Programming and consulting the schedule timer 10
- Programming 11
- Consulting programmed actions 13
- Tips and tricks 13
- Field settings 14
- Ield settings 14
- Procedure 14
- Detailed description 15
- Field settings table 19
- Aintenance 21
- Disposal requirements 21
- Important information regarding the refrigerant used 21
- Isposal requirements 21
- Maintenance 21
- Maintenance activities 21
- Roubleshooting 21
- Standstill 21
- Troubleshooting 21
Похожие устройства
- Daikin EKCBH008BCV3 Инструкция по монтажу
- Daikin BEVN32AV1 Инструкция по монтажу
- Daikin BEVN50AV1 Инструкция по монтажу
- Daikin BEVN125AV1 Инструкция по монтажу
- Daikin BRC1E53A7 Инструкция по монтажу
- Daikin BRC1E53A7 Руководство по применению для установщика
- Daikin BRC1E53A7 Руководство по применению для пользователя
- Daikin BRC1E53B Инструкция по монтажу
- Daikin BRC1E53B Руководство по применению для установщика
- Garmin echo 200 Инструкция по эксплуатации
- Garmin echo 200 Инструкция по установке
- Samsung VP-DC575Wi Инструкция по эксплуатации
- Samsung VP-DC575WB Инструкция по эксплуатации
- Samsung VP-DC565WB(i) Инструкция по эксплуатации
- Samsung VP-DC565W(i) Инструкция по эксплуатации
- Samsung VP-DC563(i) Инструкция по эксплуатации
- Samsung VP-DC175WB Инструкция по эксплуатации
- Samsung VP-DC175W(i) Инструкция по эксплуатации
- Samsung VP-DC173(i) Инструкция по эксплуатации
- Samsung VP-DC172W Инструкция по эксплуатации