Daikin EKCBH008BCV3 [5/24] Name and function of buttons and icons
![Daikin EKCBX008BCV3 [5/24] Name and function of buttons and icons](/views2/1789211/page5/bg5.png)
EKCBX/H008BCV3
Unit for air to water heat pump system
4P348534-1 – 2013.04
Operation manual
4
4.3. Name and function of buttons and icons
1. HEATING/COOLING ON/OFF BUTTON y
The ON/OFF button starts or stops the heating or cooling
function of the unit.
When the unit is connected with an external room thermostat,
this button is not operable and the icon e is shown.
Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).
2. OPERATION LED
0
The operation LED is lit during space heating or space cooling
operation. The LED blinks if a malfunction occurs. When the
LED is OFF, space heating or space cooling are inactive while
the other operation modes can still be active.
3. OPERATION MODE ICONS hcws
These icons indicate the current operation mode(s): space
heating (h), space cooling (c), domestic water heating (w) or
quiet mode (s). Within limits, different modes can be combined,
e.g. space heating and domestic water heating. The
corresponding mode icons will be displayed simultaneously.
In a heating only installation, the c icon will never be displayed.
If the domestic hot water tank is not installed, the w icon will
never be displayed.
If the solar option is installed and active, the w icon will be
blinking.
4. EXTERNAL CONTROL ICON e
This icon indicates that the room thermostat (optional) with
higher priority is controlling your installation. This external room
thermostat can start and stop the space heating/cooling
operation and change the operation mode (heating/cooling).
When the external room thermostat with a higher priority is
connected, the schedule timer for space heating and space
cooling will not function.
When the benefit kWh power rate signal is sent, the centralised
control indication e will flash to indicate that benefit kWh power
rate is active.
5. DAY OF THE WEEK INDICATOR
1234567
This indicator shows the current weekday.
When reading or programming the schedule timer, the indicator
shows the set day.
6. CLOCK DISPLAY 8
The clock display shows the current time.
When reading or programming the schedule timer, the clock
display shows the action time.
7. SCHEDULE TIMER ICON
p
This icon indicates that the schedule timer is enabled.
8. ACTION ICONS Q
These icons indicate the programming actions for each day of
the schedule timer.
9. OFF ICON x
This icon indicates that the OFF action is selected when
programming the schedule timer.
10. INSPECTION REQUIRED k and l
These icons indicate that inspection is required on the
installation. Consult your dealer.
11. SET TEMPERATURE DISPLAY 9
The display shows the current space heating/cooling set
temperature of the installation.
12. SETTING $
Not used. For installation purposes only.
13. NOT AVAILABLE n
This icon is displayed whenever a non-installed option is
addressed or a function is not available.
14. DEFROST/STARTUP MODE ICON d
This icon indicates that the defrost/startup mode is active.
15. COMPRESSOR ICON ç
This icon indicates that the compressor in the outdoor unit of the
installation is active.
16. BACKUP HEATER STEP ONE ( OR STEP TWO §
These icons indicate that the backup heater (if installed) is
operating on low capacity (() or on high capacity (§). The
backup heater provides extra heating capacity in case of low
ambient outdoor temperature (high heating load).
17. BOOSTER HEATER ICON m
This icon indicates that the booster heater is active. The booster
heater provides auxiliary heating for the domestic hot water
tank.
The booster heater is located in the domestic hot water tank.
The icon is not used when the domestic hot water tank is not
installed.
18. PUMP ICON é
This icon indicates that the circulation pump is active.
19. OUTDOOR TEMPERATURE DISPLAY u
When this icon is flashing, the outdoor ambient temperature is
displayed.
20. WEATHER DEPENDENT SET POINT ICON a
This icon indicates that the controller will adapt the temperature
set point automatically, based on the outdoor ambient
temperature.
21. TEMPERATURE ICON b
This icon is displayed when the water outlet temperature of the
indoor unit, the outdoor ambient temperature and the domestic
hot water tank temperature are shown.
The icon is also displayed when the temperature set point is set
in schedule timer programming mode.
22. TEST OPERATION ICON
t
This icon indicates that the unit runs in test mode.
23. FIELD SET CODE
;
This code represents the code from the field set list. Refer to the
"Field settings table" on page 18.
24. ERROR CODE
:
This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.
INFORMATION
Remark that pushing the y button has no influence
on the domestic water heating. Domestic water
heating is only switched on or off by means of the
v button.
1173
5 6 248
13
25
26
11
19
21
14
35
4
7
9
12
10
22
34
27
28
23
20
33
32
31
29
30
2161815
Содержание
- Operation manual 1
- Unit for air to water heat pump system 1
- Definitions 2
- Efinitions 2
- Meaning of used terms 2
- Meaning of warnings and symbols 2
- Operation manual 2
- Afety precautions 3
- General safety precautions 3
- Introduction 3
- Ntroduction 3
- This manual 3
- This unit 3
- Features and functions 4
- Introduction 4
- Operating the digital controller 4
- Operating the unit 4
- Perating the unit 4
- Name and function of buttons and icons 5
- Setting the clock 6
- Setting the schedule timer 6
- Setting up the controller 6
- Description of the operation modes 7
- Domestic water heating operation 7
- Domestic water heating operation w 7
- Powerful domestic water heating operation 7
- Space cooling operation 7
- Space cooling operation c 7
- Space heating operation 7
- Space heating operation h 7
- Controller operations 8
- Manual operation 8
- Quiet mode operation 8
- Quiet mode operation s 8
- Schedule timer operation 9
- Getting started 10
- Programming and consulting the schedule timer 10
- Programming 11
- Consulting programmed actions 13
- Tips and tricks 13
- Field settings 14
- Ield settings 14
- Procedure 14
- Detailed description 15
- Field settings table 19
- Aintenance 21
- Disposal requirements 21
- Important information regarding the refrigerant used 21
- Isposal requirements 21
- Maintenance 21
- Maintenance activities 21
- Roubleshooting 21
- Standstill 21
- Troubleshooting 21
Похожие устройства
- Daikin EKCBH008BCV3 Инструкция по монтажу
- Daikin BEVN32AV1 Инструкция по монтажу
- Daikin BEVN50AV1 Инструкция по монтажу
- Daikin BEVN125AV1 Инструкция по монтажу
- Daikin BRC1E53A7 Инструкция по монтажу
- Daikin BRC1E53A7 Руководство по применению для установщика
- Daikin BRC1E53A7 Руководство по применению для пользователя
- Daikin BRC1E53B Инструкция по монтажу
- Daikin BRC1E53B Руководство по применению для установщика
- Garmin echo 200 Инструкция по эксплуатации
- Garmin echo 200 Инструкция по установке
- Samsung VP-DC575Wi Инструкция по эксплуатации
- Samsung VP-DC575WB Инструкция по эксплуатации
- Samsung VP-DC565WB(i) Инструкция по эксплуатации
- Samsung VP-DC565W(i) Инструкция по эксплуатации
- Samsung VP-DC563(i) Инструкция по эксплуатации
- Samsung VP-DC175WB Инструкция по эксплуатации
- Samsung VP-DC175W(i) Инструкция по эксплуатации
- Samsung VP-DC173(i) Инструкция по эксплуатации
- Samsung VP-DC172W Инструкция по эксплуатации