Daikin ADEQ100A7VEB [4/12] Installation manual
![Daikin ADEQ100A7VEB [4/12] Installation manual](/views2/1792257/page4/bg4.png)
Installation manual
1
ADEQ71~125A7VEB
Split System air conditioners
4P335705-1 – 2012.11
CONTENTS Page
Before installation.............................................................................. 1
Selecting installation site................................................................... 2
Preparations before installation......................................................... 2
Indoor unit installation ....................................................................... 3
Refrigerant piping work ..................................................................... 3
Drain piping work .............................................................................. 4
Electric wiring work ........................................................................... 5
Wiring example and how to set the remote controller ....................... 6
Wiring example ................................................................................. 7
Test operation.................................................................................... 8
Wiring diagram .................................................................................. 8
The English text is the original instruction. Other languages are
translations of the original instructions.
BEFORE INSTALLATION
■ Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.
■ Refer to the installation manual of the outdoor unit for items not
described in this manual.
■ Caution concerning refrigerant series R410A:
The connectable outdoor units must be designed exclusively for
R410A.
■ Sound level is less than 70 dB(A).
Precautions
■ Do not install or operate the unit in rooms mentioned below.
• Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)
• Where corrosive gas like sulphurous gas exists. (Copper
tubing and brazed spots may corrode.)
• Where volatile flammable gas like thinner or gasoline is used.
• Where machines generating electromagnetic waves exist.
(Control system may malfunction.)
• The unit should be installed at least 2.5 m from the floor.
• Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories).
Also in vehicles or vessels.
■ Do not install accessories on the casing directly. Drilling holes in
the casing may damage electrical wires and consequently cause
fire.
Accessories
Check if the following accessories are included with your unit.
Optional accessories
Select an optional remote controller according to customer request
and install in an appropriate place.
Refer to catalogues and technical literature for selecting a suitable
remote controller.
ADEQ71A7VEB
ADEQ100A7VEB
ADEQ125A7VEB
Split System air conditioners
Installation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.
Metal clamp
1 piece
Drain hose
1 piece
Washer for
hanging bracket
8 pieces
Medium
sealing pad
2 pieces
Insulation for fitting
Large sealing pad
1 piece
for gas pipe
1 piece
for liquid pipe
1 piece
Installation and
operation manual
Screws for duct flanges
1 set
16 pieces.
Wire for common
power supply
2 pieces.
12
Содержание
- Installation manual 1
- Split system air conditioners 1
- Adeq71a7veb adeq100a7veb adeq125a7veb 3
- Daikin europe n v 3
- Director 3
- Electromagnetic compatibility 2004 108 ec 3
- En60335 2 4 3
- Jean pierre beuselinck 3
- Low voltage 2006 95 ec 3
- Machinery 2006 42 ec 3
- Ostend 1st of february 2013 3
- P335707 1 3
- P335707 1_adeq71 125a7veb fm page 1 monday november 26 2012 11 00 am 3
- Accessories 4
- Before installation 4
- Efore installation 4
- Installation manual 4
- Optional accessories 4
- Precautions 4
- Electing installation sit 5
- For the following items take special care during construction and check after installation is fi 5
- For the following items take special care during construction and check after installation is finished 5
- Installation with rear duct and duct service opening see figure 6b 5
- Installation with rear duct no duct service opening see figure 6c 5
- Notes to the installer 5
- Preparations before installation 5
- Reparations before installation 5
- Selecting installation site 5
- Standard rear suction see figure 6a 5
- Efrigerant piping work 6
- Indoor unit installation 6
- Ndoor unit installation 6
- Refrigerant piping work 6
- Cautions for brazing 7
- Drain piping work 7
- Rain piping work 7
- Electric wiring work 8
- General instructions 8
- Lectric wiring work 8
- Testing of drain piping 8
- When electric wiring work is not finished 8
- When electric wiring work is finished 8
- Electrical characteristics 9
- How to connect wiring 9
- Iring example and how to set the remote controller 9
- Precautions 9
- Specifications for field wire 9
- Specifications for field wire 9
- Wiring example and how to set the remote controller 9
- Complete system example 3 systems 10
- Control by 2 remote controllers controlling 1 indoor unit by 2 remote controllers 10
- External static pressure setting using the remote controller 10
- Field setting 10
- Iring example 10
- Precautions 10
- Setting air filter sign 10
- Setting air filter sign 10
- Setting for optional accessories 10
- Wiring example 10
- Est operation 11
- Iring diagram 11
- Test operation 11
- Wiring diagram 11
Похожие устройства
- Daikin ADEQ100A7VEB Инструкция по эксплуатации
- Daikin ADEQ125A7VEB Инструкция по монтажу
- Daikin ADEQ125A7VEB Инструкция по эксплуатации
- Daikin ADEQ71B2VEB Инструкция по эксплуатации
- Daikin ADEQ71B2VEB Инструкция по монтажу
- Daikin ADEQ100B2VEB Инструкция по эксплуатации
- Daikin ADEQ100B2VEB Инструкция по монтажу
- Daikin ADEQ125B2VEB Инструкция по эксплуатации
- Daikin ADEQ125B2VEB Инструкция по монтажу
- Daikin ADEQ35C2VEB Инструкция по монтажу
- Daikin ADEQ35C2VEB Инструкция по эксплуатации
- Daikin ADEQ50C2VEB Инструкция по монтажу
- Daikin ADEQ50C2VEB Инструкция по эксплуатации
- Daikin ADEQ60C2VEB Инструкция по монтажу
- Daikin ADEQ60C2VEB Инструкция по эксплуатации
- Daikin ADEQ71C2VEB Инструкция по монтажу
- Daikin ADEQ71C2VEB Инструкция по эксплуатации
- Daikin ADEQ100C2VEB Инструкция по монтажу
- Daikin ADEQ100C2VEB Инструкция по эксплуатации
- Daikin ADEQ125C2VEB Инструкция по монтажу