Daikin FBQ45EAVAK Инструкция по монтажу онлайн [3/60] 606631
![Daikin FBQ45EAVAK Инструкция по монтажу онлайн [3/60] 606631](/views2/1792705/page3/bg3.png)
English 2
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes.
Failure to do so during installation work may result in the unit falling and causing accidents.
• Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried
out by qualified personnel according to local laws and regulations and this installation manual.
An insufficient power supply capacity or improper electrical construction may
lead to electric shocks or fire.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shocks or fire.
A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install the earth leakage breaker.
Failure to install the earth leakage breaker may result in electric shocks or fire.
• Be sure to switch off the unit before touching any electrical parts.
Touching a live part may result in electric shock.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the te
rminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the
wires so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or overheating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room an
d comes into contact with a source
of fire, such as a fan heater, stove or cooker.
• Do not touch any refrigerant that leaks out of refrigerant piping joints or connections.
Touching it may cause frostbite.
CAUTION
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and
insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Install the indoor and outdoor units, power cord and connecting wires at least 1 meter away from televisions
or radios to prevent picture interference and noise.
(Depending on the incoming signal strength, a distance of 1 meter may not be sufficient to eliminate noise.)
• Install the indoor unit as far away from fluorescent lamps as possible.
Remote controller (wireless kit) transmitting distance can be shorter than expected in rooms with electronic
fluorescent lamps (inverter or rapid start types).
01_EN_3PN06583-10W.fm Page 2 Thursday, March 24, 2011 9:03 AM
Consult your local dealer regarding what to do in case of refrigerant leakage, when the air coditioner is to
be installed in a small room, it is necessary to take proper measures so that the amount of any leaked
refrigerant does not exceed the concentration limit in the event of leakage. Otherwise, this may lead to
an accident due to oxygen depletion.
•
In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Do not allow children to climb on the outdoor unit and avoid placing objects on the unit.
Injury may result if the unit becomes loose and falls.
Make sure
to provide for adequate measure in order to prevent that the outdoor unit be used as a
shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct
the customer to keep the area around the unit clean.
Install in a machine room that is free of moisture. The unit is designed for indoor use.
Disposal requirements
Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in
accordance with relevant local and national legislation.
•
•
•
•
•
Содержание
- Installation manual 1
- Split system air conditioner 1
- ءﺍﻮﻬﻟﺍ ﻒﻴﻴﻜﺗ ﺯﺎﻬﺟﻢﺴﻘﻨﻤﻟﺍ ﻡﺎﻈﻨﻟﺍ 1
- ﺐﻴﻛﺮﺘﻟﺍ ﻞﻴﻟﺩ 1
- Contents 2
- Safety precautions 2
- Special notice of product 4
- 1 accessories 5
- 24 type 36 45 48 type 5
- Before installation 5
- Small gray 5
- 2 optional accessories 6
- Brc4c62 cannot be used for the indoor unit fbq48eavmk if required use wireless type brc4c64 6
- For the following items take special care during construction and check after installation is finished 6
- Operation manual installation manual 6
- 3 note to the installer 7
- Selecting installation site 7
- Preparations before installation 8
- Indoor unit installation 10
- Coat here with ester or ether oil 11
- Flare nut 11
- Piping union 11
- Refrigerant piping work 11
- Spanner 11
- Torque wrench 11
- Accessory drain hose 2 14
- Accessory metal clamp 1 14
- Downward slope of at least 1 100 14
- Drain piping work 14
- Drain socket 14
- Drain socket cover for transportation 14
- Refrigerant piping 14
- Screw 4 portions 14
- Supporting hanger 14
- Air outlet 15
- Ceiling slab 15
- Concentrated drain piping 15
- Drain hose 2 accessory 15
- Drain pan 15
- Drain socket plastic water container 15
- Maintain a downward slope of at least 1 100 so that no air bank will be formed 15
- Metal clamp 1 accessory 15
- Min 100 mm 15
- Refrigerant piping 15
- Support bracket 1 1 m 15
- The drain piping will be clogged with water and water leakage may result if the water is accumulated in the drain piping 15
- Water inlet 15
- Water inlet lid 15
- Accessory 16
- Accessory screws for duct flanges 3 16
- Air inlet air outlet 16
- Canvas duct field supply 16
- Duct work 16
- Flange on air inlet side provided with the unit 16
- Flange on air outlet side provided with the unit 16
- Insulation material field supply 16
- Large sealing pad 6 accessory 16
- Make sure that the seam faces upward 16
- Metal clamp 1 accessory 16
- Mm max 16
- Screws for duct flanges 3 16
- 1 connection of wiring between units earth wire and for the remote controller cord 17
- Electric wiring work 17
- Screw 3 portions 17
- Wiring example and how to set the remote controller 17
- Ground wiring high voltage 18
- High voltage wiring inlet 18
- Low voltage 18
- Low voltage wiring inlet remote controller wiring 18
- Attach insulation sleeve 20
- Clamp 8 accessory 20
- Connect wires of the same gauge to both side good 20
- Do not connect wires of different gauges wrong 20
- Do not connect wires of the same gauge to one side wrong 20
- Electric wire round crimp style terminal 20
- Fixing use 20
- Good wrong wrong 20
- Remote controller wiring 20
- Wire fixing bracket 12 accessory 20
- Wire fixing screw 13 accessory 20
- Wiring the units power supply wiring ground wiring 20
- Earth leakage breaker 21
- Indoor unit 21
- Main power supply 21
- Outdoor unit 21
- Pair type 21
- Power supply single phase 50hz 60hz 220 2 4 0v 230v 21
- Remote controller optional accessory 21
- Wiring example 21
- Group control 22
- Group control remote controller 22
- Indoor unit 1 22
- Indoor unit 1 indoor unit 2 22
- Indoor unit 16 22
- Indoor unit 2 22
- Lower part of remote controller insert the screwdriver here and gently work off the upper part of remote controller 22
- Outdoor unit 1 outdoor unit 2 outdoor unit 16 22
- Terminal for remote controller wiring to next unit 22
- Upper part of remote controller 22
- Factory setting 23
- Field setting 23
- Only one remote controller needs to be changed if factory settings have remained untouched 23
- Outdoor unit 23
- Remote controller pc board 23
- Terminal for remote controller wiring 23
- 1 troubleshooting 26
- After leaving 10 seconds or 26
- Code display 26
- Display 26
- Error code 26
- Field setting 26
- Indoor unit type 26
- Measures 26
- Mode switching 26
- More the mode returns to the normal operating mode 26
- Normal operating mode test run 26
- Once once 26
- Outdoor unit type 26
- Refer to the section of for the following items take special care during construction and check after installation is finished 26
- Test operation 26
- 2 malfunction code list 27
- ١ ﺔﻣﻼﺴﻟﺍ ﺕﺎﻃﺎﻴﺘﺣﺍ 31
- ﺕﺎﻳﻮﺘﺤﻤﻟﺍ 31
- ﺞﺘﻨﻤﻠﻟ ﺹﺎﺧ ﺭﺎﻌﺷﺇ 33
- ﺐﻴﻛﺮﺘﻟﺍ ﻞﺒﻗ ٢ 34
- ﺕﺎﻘﺤﻠﻤﻟﺍ ١ ٢ 34
- ﺐﻴﻛﺮﺘﻟﺍ ﻦﻣ ءﺎﻬﺘﻧﻻﺍ ﺪﻌﺑ ﺎﻬﻨﻣ ﻖﻘﺤﺘﻟﺍﻭ ﺐﻴﻛﺮﺘﻟﺍ ﺔﻴﻠﻤﻋ ﻝﻼﺧ ﺭﺬﺤﻟﺍ ﻲﺧﻮﺗ ﺐﺠﻳ ﺔﻴﻟﺎﺘﻟﺍ ﻁﺎﻘﻨﻠﻟ 35
- ﺔﻳﺭﺎﻴﺘﺧﺍ ﺕﺎﻘﺤﻠﻣ ٢ ٢ 35
- ﺐﻴﻛﺮﺘﻟﺍ ﻊﻗﻮﻣ ﺪﻳﺪﺤﺗ ٣ 36
- ﺐﻴﻛﺮﺘﻟﺎﺑ ﻡﻮﻘﻴﺳ ﻦﻣ ﻰﻟﺇ ﺔﻈﺣﻼﻣ ٣ ٢ 36
- ٧٠٠ ٦٣١ 37
- ﺐﻴﻛﺮﺘﻟﺍ ﻞﺒﻗ ﺕﺍﺮﻴﻀﺤﺘﻟﺍ ٤ 37
- ٧٠٠٧٠٠ 38
- ﺔﻴﻠﺧﺍﺪﻟﺍ ﺓﺪﺣﻮﻟﺍ ﺐﻴﻛﺮﺗ ٥ 39
- ﺪﻳﺮﺒﺘﻟﺍ ﺐﻴﺑﺎﻧﺃ ﻞﻴﺻﻮﺗ ﻝﺎﻤﻋﺃ ٦ 40
- ٠ ٤ ٠ ٨ 41
- ﻒﻳﺮﺼﺘﻟﺍ ﺐﻴﺑﺎﻧﺃ ﻞﻴﺻﻮﺗ ﻝﺎﻤﻋﺃ ٧ 43
- ﻡ ١ ٥ ١ 43
- ءﺍﻮﻬﻟﺍ ﻯﺮﺠﻣ ﻝﺎﻤﻋﺃ ٨ 45
- ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ ﻙﻼﺳﻷﺍ ﻞﻴﺻﻮﺗ ﻝﺎﻤﻋﺃ ٩ 46
- ﺪﻌ ﺑ ﻦﻋ ﻢﻜﺤﺘﻟﺍ ﺓﺪﺣﻭ ﻦﻴﻴﻌﺗ ﺔﻴﻔﻴﻛﻭ ﻙﻼﺳﻷﺍ ﻞﻴﺻﻮﺘﻟ ﺝﺫﻮﻤﻧ ١٠ 46
- ﻙﻼﺳﻷﺍ ﻞﻴﺻﻮﺘﻟ ﺝﺫﻮﻤ 50
- ﻞﻘﺤﻟﺍ ﺩﺍﺪﻋﺇ ١١ 52
- ﺎﻬﺣﻼﺻﺇﻭ ءﺎﻄﺧﻷﺍ ﻑﺎﺸﻜﺘﺳﺍ ١ ١٢ 55
- ﺭﺎﺒﺘﺧﻻﺍ ﺔﻴﻠﻤﻋ ١٢ 55
Похожие устройства
- Daikin FBQ48EAVAK Инструкция по эксплуатации
- Daikin FBQ48EAVAK Инструкция по монтажу
- Daikin FBQ48EAVMK Инструкция по эксплуатации
- Daikin FBQ48EAVMK Инструкция по монтажу
- Daikin FCAHG100FVEB Общие правила техники безопасности
- Daikin FCAHG100FVEB Инструкция по эксплуатации
- Daikin FCAHG100FVEB Руководство по применению для установщика
- Daikin FCAHG125FVEB Общие правила техники безопасности
- Daikin FCAHG125FVEB Инструкция по эксплуатации
- Daikin FCAHG125FVEB Руководство по применению для установщика
- Daikin FCAHG140FVEB Общие правила техники безопасности
- Daikin FCAHG140FVEB Инструкция по эксплуатации
- Daikin FCAHG140FVEB Руководство по применению для установщика
- Daikin FCAHG71FVEB Общие правила техники безопасности
- Daikin FCAHG71FVEB Инструкция по эксплуатации
- Daikin FCAHG71FVEB Руководство по применению для установщика
- Daikin FCAHG71GVEB Общие правила техники безопасности
- Daikin FCAHG71GVEB Инструкция по эксплуатации
- Daikin FCAHG71GVEB Инструкция по монтажу