Daikin FDYM60JEVLK Инструкция по монтажу онлайн [18/30] 606811

Daikin FDYM20JEVLK Инструкция по монтажу онлайн [18/30] 606806
1-16
FDYM50JEVLK - RYD50JETLK
FDYM60JEVLK - RYD60JETLK
Power Supply Cable
Outdoor Coil Sensor
Interconnection cable
Indoor unit
Terminal Block
Outdoor unit
Terminal Block
Model Indoor FDYM50JEVLK FDYM60JEVLK
Outdoor RYD50JETLK RYD60JETLK
Voltage range ** Indoor
220V/1Ph/60Hz+!
Outdoor
220V/3N~/60Hz+!
Power supply cable size * mm
2
Number of conductors
6.0
4
6.0
4
Interconnection cable size * mm
2
Number of conductors
2.5
4 & 3
2.5
4 & 3
Recommended time delay fuse* A 35 35
Model Indoor FDYM40JEVLK
Outdoor RYD40JEVLK
Voltage range** Indoor
220V/1Ph/60Hz+!
Outdoor
220V/1Ph//60Hz+!
Power supply cable size* mm
2
Number of conductors
6.0
3
Interconnection cable size* mm
2
Number of conductors
2.5
4 & 3
Recommended time delay fuse* A 35
Power Supply Cable
Interconnection cable
Outdoor unit
Terminal Block
Indoor unit
Terminal Block
FDYM40JEVLK - RYD40JEVLK
Outdoor Coil Sensor
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
N
L
COMP
OF
4WV
A
T
S
R
N
L
COMP
OF
4WV
A
N
L
COMP
OF
4WV
A
A
4WV
OF
COMP
L
N
N
L
1 IM-CCC-0311(0)-DAIKIN (SASO).i16 16 6/9/11 10:07:40 AM