Daikin FDYM60JEVLK [17/30] English

Daikin FDYM20JEVLK [17/30] English
1-15
English
FDYM20JEVLK - RYD20JEVLK
FDYM25JEVLK - RYD25JEVLK
Model Indoor FDYM20JEVLK FDYM25JEVLK
Outdoor RYD20JEVLK RYD25JEVLK
Voltage range**
Indoor
220V/1Ph/60Hz+!
Outdoor
220V/1Ph/60Hz+!
Power supply cable size* mm
2
Number of conductors
2.5
3
2.5
3
Interconnection cable size* mm
2
Number of conductors
1.0
6
1.0
6
Recommended time delay fuse* A 20 25
Power Supply
Cable
Interconnection
cable
Outdoor unit
Terminal Block
Indoor unit
Terminal Block
Model Indoor FDYM30JEVLK
Outdoor RYD30JEVLK
Voltage range** Indoor
220V/1Ph/60Hz+!
Outdoor
220V/1Ph/60Hz+!
Power supply cable size* mm
2
Number of conductors
4.0
3
Interconnection cable size* mm
2
Number of conductors
2.5
3 & 3
Recommended time delay fuse* A 30
Power Supply Cable
Interconnection cable
Outdoor unit
Terminal Block
Indoor unit
Terminal Block
FDYM30JEVLK - RYD30JEVLK
Outdoor Coil Sensor
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
N
L
N1
L1
COMP
OF
4WV
N
N
L
COMP
OF
4WV
Outdoor Coil Sensor
N
N
L
COMP
OF
4WV
L
N
L
COMP
OF
4WV
N
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
1 IM-CCC-0311(0)-DAIKIN (SASO).i15 15 6/9/11 10:07:40 AM