8 | Configuration
Installer reference guide
173
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
Parameter Setting Range Default
settings
Description
Minimum outside
temperature of the heat curve
–30°C~10°C –7°C Do NOT modify this setting on
the boiler. Use the user
interface instead.
Maximum outside
temperature of the heat curve
15°C~30°C 25°C Do NOT modify this setting on
the boiler. Use the user
interface instead.
Space heating pump post
purge period
0~15min 1min Changing this setting has no
effect on the operation of the
unit.
Space heating pump post
purge period after domestic
hot water operation
0~15min 1min Changing this setting has no
effect on the operation of the
unit.
Position 3-way valve or electric
valve
0~3 0 0=Powered during space
heating
1=Powered during domestic
hot water
2=Powered during every
heat demand (space heating,
domestic hot water, eco/
comfort)
3=Zone regulation
4 and higher=Not applicable
Booster 0~1 0 Changing this setting has no
effect on the operation of the
unit.
Step modulation 0~1 1 0=OFF during space heating
operation
1=ON during space heating
operation
It is recommended not to
modify this setting.
Minimal space heating rpm 23%~50% 23% Adjustment range 23~50%
(40=propane).
It is recommended not to
modify this setting in case of
natural gas.
. Minimum capacity space
heating pump
40 There is no space heating
pump in the gas boiler.
Changing this setting has no
effect.
Minimal domestic hot water
rpm
(not applicable for
Switzerland)
23%~50% 23% Adjustment range 23~50%
(40=propane).
It is recommended not to
modify this setting in case of
natural gas.