3.9.3 Injuries
What to do in case of sprains, dislocations or broken bones:
Use a splint or a bandage to immobilise the area where the injury occurred, in the position that causes less pain for the injured
person and without attempting any unnecessary and potentially harmful manoeuvres. Apply a cold pack (an ice pack or similar);
In case of an open fracture, apply pressure away from the fracture to stop the bleeding and then cover the injury with a sterile
dressing.
Bruises, crushing:
If the upper or lower extremities of a limb have been bruised and/or crushed (fingers, hands, feet, etc.), put the affected limb
immediately under (cold) running water and then apply an ice pack. Check for open wounds and/or cuts and disinfect the affected
area if necessary.
3.9.4 Bleeding
It may be necessary to apply direct pressure to the bleeding area using a sterile dressing, lift the limb and apply pressure upstream
to the origin of the bleeding with a tourniquet
Surface wounds:
Expose the wound and clean it with water, disinfect it with saline solution and medicate it, covering it with a sterile dressing. Cover
this with a bandage without tightening the bandage excessively to permit normal circulation
Deep wounds:
Wearing gloves and a facemask to protect yourself from the risk of infection is a priority. Compress the area until the bleeding stops
or the ambulance arrives by applying direct pressure or using other pressure points. Call the emergency services (each country has
its own number for the emergency services) and inform them that the person has arterial bleeding.
Do not attempt to treat the wound before the bleeding has been controlled.
Do NOT use cotton wool, alcohol or antibiotic powder to disinfect a wound.
Always remember to wear latex gloves to prevent contact with body fluids.
4 INTENDED USE
4.1 Intended use
Hawk motorpumps must not be used for any other purposes than those described in these instructions. Complying with the terms
of use, repair and maintenance specified by the Manufacturer in strict accordance are an essential element with regard to the
intended use.
The Hawk motorpumps described in these instructions were designed and built to be incorporated in cleaning
machines/equipment (high pressure cleaner). They must be used in a manner that corresponds to their technical specifications
(section 2.1.1), without unauthorised modifications and not be used for improper purposes.
The pump may ONLY be used and fitted by trained and qualified personnel who are familiar with the
information in this manual.
Do not operate the motorpump until the machine where it is fitted has been declared as compliant with
current legal standards (e.g. 2006/42/EC directive).
4.2 Improper Uses
The equipment must not be used:
By any other recipients than those referred to in 1.1.2
Содержание
120- Instructions manual
- Leuco s p a
- Instructions manual
- General information
- Aim and contents
- Structure of the manual
- Motorpumps
- Intended recipients definitions
- Storage
- Instructions manual
- Service centres
- Leuco s p a via colletta 20 42124 reggio emilia re italy
- Motorpumps
- Manufacturer
- Ec mark and certification declaration of incorporation
- Symbols used in the manual
- Instructions manual
- Motorpumps
- Guarantee
- Instructions manual
- Motorpumps
- General description
- Main parts
- Instructions manual
- Motorpumps
- Technical characteristics
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Local conditions
- Motorpumps
- Instructions manual
- Instructions manual
- Pressurised liquids
- Motorpumps
- High temperatures
- General safety instructions
- Vibration
- Stability
- Safety
- Instructions manual
- Residual risks
- Motorpumps
- Working safely
- Instructions manual
- Personal protective equipment
- Motorpumps
- Safety when using the pump
- Safety when using high pressure circuits
- Packing unpacking and transport
- Motorpumps
- Instructions manual
- Safety during lifting and handling
- Rules of conduct regarding the use of high pressure lance
- Motorpumps
- Instructions manual
- This manual remains the property of the manufacturer it may not be reproduced or copied even partially
- Safety during maintenance
- Page 15 of 31
- Issue 0
- Follow the instructions below whenever carrying out any maintenance or repair work depressurise the water system and disconnect the pump from any power source before starting any maintenance or repair work
- Failure to comply with these instructions may lead to situations of extreme danger
- Each motorpump is packed so that it is protected from stress and impact and will not be damaged during transport based on the amount of goods to be shipped and the final place of destination the packed pumps can be placed on a pallet to facilitate lifting and handling when unpacking check the parts are intact and they are the correct amount if any parts are damaged or missing contact your dealer or the manufacturer for instructions dispose of packing materials correctly according to legal obligations different means of transport may be used to ship hawk motorpumps road rail sea or air depending on their final destination secure the packs to the vehicle properly during transport to prevent movement
- Cod doc m i ep 18
- As evidenced by the dimensional specifications the product described in this document requires special handling with suitable as evidenced by the dimensional specifications the product described in this document requires special handling with suitable lifting devices for example belts and hoists
- Instructions manual
- Products used
- Product labels
- Motorpumps
- First aid
- What the first aider does
- The emergency call
- Other signs on the equipment
- Motorpumps
- Instructions manual
- Motorpumps
- Intended use
- Injuries
- Instructions manual
- Improper uses
- Bleeding
- Motorpumps
- Installation and assembly
- Instructions manual
- Responsibilities of the customer user
- Motorpumps
- Instructions manual
- Pre commissioning instructions
- Motorpumps
- Long periods of inactivity
- Instructions manual
- Operation
- Motorpumps
- Instructions manual
- The table below is an example of how to choose the nozzle correctly based on the pump s specifications maximum pressure and flow rate factor the table gives an example pump with pmax 100 bar and flow rate 15 l min
- Pag 24 di 31
- Nozzle table
- Motorpumps
- Instructions manual
- Cod doc m i ep 18
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Instructions manual
- General maintenance
- Motorpumps
- Maintenance
- Motorpumps
- Instructions manual
- Instructions manual
- Trouble shooting
- Troubleshooting
- Motorpumps
- Spare parts
- Dismantling and disposal
- Motorpumps
- Instructions manual
- Attachments
Похожие устройства
-
HAWK AQUA 1320R (1450 об/мин)Деталировка -
HAWK XLT 2520IRДеталировка -
HAWK XLT 2520IRИнструкция по эксплуатации -
HAWK HD 1115RДеталировка -
HAWK HD 1115RИнструкция по эксплуатации -
HAWK XXT7015IR (1450 об/мин)Деталировка -
HAWK XXT7015IR (1450 об/мин)Инструкция по эксплуатации -
HAWK XXT5520IR (1450 об/мин)Деталировка -
HAWK XXT5520IR (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1320RN (1450 об/мин)Деталировка -
HAWK AQUA 1320RN (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1520RN (1450 об/мин)Деталировка
Узнайте, как правильно использовать насосы, а также оказать первую помощь при травмах. Важные советы по уходу и безопасности для эффективной работы.