6 MAINTENANCE
Use the special tools provided in the product’s tool-kit for pump maintenance, as this will facilitate the maintenance of certain
parts. If the special tool-kit is not available, standard tools can be used (screwdrivers, pin punches etc) but take care not to damage
the pump’s parts.
Follow the instructions below during maintenance or repairs:
Before starting work, hang a "MACHINE UNDERGOING MAINTENANCE" sign in a prominent position
Before intervening, shut off the supply from the power network, wait until the moving parts have come to a stop and
check that the these cannot be restarted by other moving parts dragging the shaft. Wait for the surface temperature to
drop below 50°C to prevent burns
Do not use flammable products or materials
When handling lubricants, wear gloves that are resistant to mineral oils, overalls (trousers must never be tucked into
safety shoes) and goggles
Do not spill any oil or lubricant
Maintenance work may only be carried out by authorised, qualified personnel and must be noted in the
special log.
Always comply with the safety instructions in section 3.
The pump’s efficiency can be safeguarded by following the preventive maintenance schedule below:
CONTROL
DAILY
WEEKLY
50 H
500 H
1000 H*
1500 H*
CLEAN FILTERS
X
OIL LEVEL/CONDITION
X
OIL/WATER LEAKS
X
HYDRAULIC SYSTEM
X
1ST OIL CHANGE
X
CHANGE OIL
X
REPLACE SEALS
X
REPLACE CHECK VALVES
X
* Each maintenance schedule depends on the type of job that the pump is used for.
The operating cycle, the temperature and the quality of the pumped liquid, the type and quality of the supply and the condition of the
accessories used are all fundamental factors that influence the life of pump parts.
If the pump's performance deteriorates, check whether our “Troubleshooting” guide describes the source of the problem. If the pump
is running without any problems, check it after 1000 hours of operation and then every 500 hours of operation.
After completing any maintenance work, remember to adjust the control / unloader / safety valve and check the condition of the
hydraulic system and relative couplings.
The data provided is the result of the cycles verified on our testing benches, therefore any other element that differs to the parameters
used may have an impact on the life of the parts.
6.1 General maintenance
Generally speaking, the following checks must be carried out:
Check the pump is secured properly:
Check the screws securing the pump are tight
Содержание
120- Instructions manual
- Leuco s p a
- Instructions manual
- General information
- Aim and contents
- Structure of the manual
- Motorpumps
- Intended recipients definitions
- Storage
- Instructions manual
- Service centres
- Leuco s p a via colletta 20 42124 reggio emilia re italy
- Motorpumps
- Manufacturer
- Ec mark and certification declaration of incorporation
- Symbols used in the manual
- Instructions manual
- Motorpumps
- Guarantee
- Instructions manual
- Motorpumps
- General description
- Main parts
- Instructions manual
- Motorpumps
- Technical characteristics
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Local conditions
- Motorpumps
- Instructions manual
- Instructions manual
- Pressurised liquids
- Motorpumps
- High temperatures
- General safety instructions
- Vibration
- Stability
- Safety
- Instructions manual
- Residual risks
- Motorpumps
- Working safely
- Instructions manual
- Personal protective equipment
- Motorpumps
- Safety when using the pump
- Safety when using high pressure circuits
- Packing unpacking and transport
- Motorpumps
- Instructions manual
- Safety during lifting and handling
- Rules of conduct regarding the use of high pressure lance
- Motorpumps
- Instructions manual
- This manual remains the property of the manufacturer it may not be reproduced or copied even partially
- Safety during maintenance
- Page 15 of 31
- Issue 0
- Follow the instructions below whenever carrying out any maintenance or repair work depressurise the water system and disconnect the pump from any power source before starting any maintenance or repair work
- Failure to comply with these instructions may lead to situations of extreme danger
- Each motorpump is packed so that it is protected from stress and impact and will not be damaged during transport based on the amount of goods to be shipped and the final place of destination the packed pumps can be placed on a pallet to facilitate lifting and handling when unpacking check the parts are intact and they are the correct amount if any parts are damaged or missing contact your dealer or the manufacturer for instructions dispose of packing materials correctly according to legal obligations different means of transport may be used to ship hawk motorpumps road rail sea or air depending on their final destination secure the packs to the vehicle properly during transport to prevent movement
- Cod doc m i ep 18
- As evidenced by the dimensional specifications the product described in this document requires special handling with suitable as evidenced by the dimensional specifications the product described in this document requires special handling with suitable lifting devices for example belts and hoists
- Instructions manual
- Products used
- Product labels
- Motorpumps
- First aid
- What the first aider does
- The emergency call
- Other signs on the equipment
- Motorpumps
- Instructions manual
- Motorpumps
- Intended use
- Injuries
- Instructions manual
- Improper uses
- Bleeding
- Motorpumps
- Installation and assembly
- Instructions manual
- Responsibilities of the customer user
- Motorpumps
- Instructions manual
- Pre commissioning instructions
- Motorpumps
- Long periods of inactivity
- Instructions manual
- Operation
- Motorpumps
- Instructions manual
- The table below is an example of how to choose the nozzle correctly based on the pump s specifications maximum pressure and flow rate factor the table gives an example pump with pmax 100 bar and flow rate 15 l min
- Pag 24 di 31
- Nozzle table
- Motorpumps
- Instructions manual
- Cod doc m i ep 18
- Instructions manual
- Motorpumps
- Motorpumps
- Instructions manual
- Instructions manual
- General maintenance
- Motorpumps
- Maintenance
- Motorpumps
- Instructions manual
- Instructions manual
- Trouble shooting
- Troubleshooting
- Motorpumps
- Spare parts
- Dismantling and disposal
- Motorpumps
- Instructions manual
- Attachments
Похожие устройства
-
HAWK AQUA 1320R (1450 об/мин)Деталировка -
HAWK XLT 2520IRДеталировка -
HAWK XLT 2520IRИнструкция по эксплуатации -
HAWK HD 1115RДеталировка -
HAWK HD 1115RИнструкция по эксплуатации -
HAWK XXT7015IR (1450 об/мин)Деталировка -
HAWK XXT7015IR (1450 об/мин)Инструкция по эксплуатации -
HAWK XXT5520IR (1450 об/мин)Деталировка -
HAWK XXT5520IR (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1320RN (1450 об/мин)Деталировка -
HAWK AQUA 1320RN (1450 об/мин)Инструкция по эксплуатации -
HAWK AQUA 1520RN (1450 об/мин)Деталировка
Узнайте, как правильно обслуживать насосы с помощью нашего подробного руководства. Следуйте инструкциям по безопасности и поддерживайте эффективность оборудования.