General-Fujitsu AOHZ24LBT [11/27] Outdoor unit inverter assy ez 006rhue
![General-Fujitsu AOHZ24LBT [11/27] Outdoor unit inverter assy ez 006rhue](/views2/1804969/page11/bgb.png)
D100
D25XB60
+
-
2
3
4
1
TM101
TM102
EMI FILTER
COMPRESSOR
C M
2
3
1
2
3
1
UL1015 AWG14
RED
WHITE
BLACK
RED
WHITE
BLACK
B
W303
B
W304
B
W305
B
W301
B
W302
B
W306
B
W307
B
W12
B
W13
B
W7
B
W8
B
W4
SERIAL
RED
CN801 B5 (7-2.3) B-XASK-1-A
WHITE
CN700 B6B-XARK-1-A
RED
CN500 179844-1 (AC type)
WHITE
CN90 B2B-XARK-1-A
RED
CN60 B2B-XH-AM YEL
YELLOW
CN61 B2B-XH-AM RED
RED
CN62 B2B-XAEK-1-A
BLUE
CN64 B2B-XAMK-1-A
GREEN
TM601 TM600
CT IN / OUT
CN110
B2P3-VH-B-Y
YELLOW
AC VOLT IN
CN1
B2B-XH-AM BLK
BLACK
POWER RELAY CONTROL
R200
ZPR0YC400A300
L1
L2
+
-
CHOKE COIL
L = 0.3MH 30A
P
N1
N2
I O
UL1015
AWG14
WHITE
UL1015
AWG14
WHITE
B
W17
B
W16
CN400
B4B-XASK-1-A
WHITE
ACTPM CONTROL
CN200
B2P4-VH-B-M
WHITE
DC VOLT IN
CN40
B10B-XASK-1
WHITE
IPM CONTROL
CN42
B2B-XH
WHITE
PEAK LOAD CURRENT
CN303
B2B-XH-AM
WHITE
PEAK LOAD CURRENT
CN301
B10B-XASK-1
WHITE
IPM CONTROL
UL1015 AWG14 RED
UL1015 AWG14 BLACK
UL1015 AWG14 BROWN
UL1015 AWG14 ORANGE
B
W17
B
W18
B
W1
B
W2
B
W3
EMI FILTER
EARTH
EMI FILTER
EMI FILTER
B
W29
B
W28
CN100
B
W19
B
W20
B
W21
B
W9
CT IN / OUT
B
W25
B
W26
DC FAN MOTOR
EXPANSION VALVE
4-WAY VALVE
PRESSURE SWITCH
DISCHARGE TEMP. THERMISTOR
PIPE TEMP. THERMISTOR
OUTDOOR TEMP. THERMISTOR
COMPRESSOR TEMP. THERMISTOR
BLACK
BLACK
RED
RED
WHITE
YELLOW
ORANGE
BLUE
BROWN
RED
BROWN
YELLOW
WHITE
BLACK
RED
BROWN
BROWN
BLACK
BLACK
BLUE
BLUE
BROWN
BROWN
F M
M
F100
FSL 250 3.15 (EM)
(250V 3.15A)
F200
25A-250V
UL1015
AWG14
BLACK
UL1015
AWG16
GREEN
UL1015
AWG14
BLACK
UL1015
AWG20
BLACK
UL1015
AWG14
WHITE
UL1015
AWG20
WHITE
UL1015
AWG20
RED
INDOOR UNIT
POWER SOURCE
AC230V
50Hz
UL1015
AWG14
YELLOW
UL1015
AWG14
BLUE
1
2
2
1
UL1007 AWG24 BROWN
UL1007 AWG24 RED
UL1007 AWG24 BROWN
UL1007 AWG24 RED
UL1007 AWG24 ORANGE
UL1007 AWG24 YELLOW
UL1007 AWG24 GREEN
UL1007 AWG24 BLUE
UL1007 AWG24 PURPLE
UL1007 AWG24 GRAY
UL1007 AWG24 BLACK
UL1007 AWG24 WHITE
UL1015 AWG20 BLACK
UL1015 AWG20 WHITE
UL1007 AWG24 YELLOW
UL1007 AWG24 ORANGE
UL1007 AWG24 RED
UL1007 AWG24 BROWN
03 VH / SIN
1015 L250
UL1007 AWG24 WHITE
UL1007 AWG24 WHITE
UL1015 AWG20 ORANGE
UL1015 AWG20 ORANGE
UL1015 AWG20 BLACK
UL1015 AWG20 WHITE
UL1015 AWG14 BLACK
UL1015 AWG14 GRAY
N
L
3
2
1
UL1015
AWG14
WHITE
UL1015
AWG14
VIOLET
ACTPM
I C 404
SACT32010F1
CAPACITOR PCB ASSY
K05FB-0500HUE-P0
I P M
TRANSISTIR PCB ASSY
K05CZ-0503HUE-TR0
POWER SUPPLY PCB
K05CW-0603HUE-FL0
CONTROLLER PCB ASSY ( MAIN PCB )
K05CU-0602HUE-C1
OUTDOOR UNIT
INVERTER ASSY : EZ-006RHUE
2006.10.18 10
Содержание
- Ceiling wal 1
- Inverter 1
- Split type room air conditioner 1
- Compressor 2
- Dimensions and weight 2
- Electrical data 2
- Fan motor 2
- Noise level 2
- Note noise was measured in accordance with jis standards japan high2 means when ability measurement 2
- Refrigerant charge r410a 2
- Specifications 2
- Dimensions 3
- Refrigerant pipe diameter liquid 1 4 6 5 mm gas 5 8 15 8 mm 5
- Refrigerant system diagram 5
- Circuit diagram 6
- Indoor unit 6
- Outdoor unit 6
- 2 3 l n 7
- Capacitor pcb 7
- Choke coil 7
- Compressor 7
- Compressor temp thermistor 7
- Connector 7
- Controller pcb 7
- Discharge temp thermistor 7
- Expansion valve 7
- Fan motor 7
- Fuse 250v 25a 7
- High pressur switch 7
- I p m pcb 7
- Main pcb 7
- Outdoor temp thermistor 7
- Outdoor unit 7
- Pipe temp thermistor 7
- Posistor 7
- Power source 7
- Power supply pcb 7
- Terminal 7
- To indoor unit 7
- Way valve 7
- Control unit ez 0060bhse 8
- Controller pcb assy k05ds 0600hse c1 8
- Indoor pcb circuit diagram 8
- Indoor unit controller pcb assembly k05ds 0600hse c1 9
- Power source ac230v 50hz 9
- Indoor unit indicator pcb assembly k04du 0500hse d0 10
- 0 8 10 11
- Actpm i c 404 11
- Capacitor pcb assy 11
- Controller pcb assy main pcb 11
- K05cu 0602hue c1 11
- K05cz 0503hue tr0 11
- K05fb 0500hue p0 11
- Outdoor unit inverter assy ez 006rhue 11
- Power supply pcb k05cw 0603hue fl0 11
- Sact32010f1 11
- Transistir pcb assy 11
- 0 8 11 12
- Outdoor unit controller pcb assembly k05cu 0602hue c1 12
- 0 8 12 13
- Comp position detector 13
- Db circuit 13
- Inverter 13
- Outdoor unit transistor pcb assembly k05cz 0503hue tr0 13
- 0 8 13 14
- Outdoor unit power supply pcb assembly k05cw 0603hue fl0 14
- 0 8 14 15
- Outdoor unit capacitor pcb assembly k05fb 0500hue p0 15
- Error contents 16
- Disassembly illustration 17
- Indoor unit 17
- Indoor unit casing assy 18
- Indoor unit 19
- 0 1 23 24
- Indoor unit 24
- Parts list 24
- Description 25
- No aohz24lbt q ty 25
- Outdoor unit 25
- Part no 25
- Ref ord 25
- Name and shape q ty name and shape q ty 26
- Standard accessories 26
Похожие устройства
- General-Fujitsu AOHZ24LBT Технические данные
- General-Fujitsu AOHZ24LBT Брошюра
- General-Fujitsu AWHZ24LBC Сервис мануал
- General-Fujitsu AWHZ24LBC Технические данные
- General-Fujitsu AWHZ24LBC Брошюра
- General-Fujitsu ARH30LUAN Сервис мануал
- General-Fujitsu ARH30LUAN Технические данные
- General-Fujitsu ARH36LUAN Технические данные
- General-Fujitsu ARH36LUAN Сервис мануал
- General-Fujitsu ARH30LUAN Брошюра
- General-Fujitsu ARH36LUAN Брошюра
- General-Fujitsu ARH45LUAN Технические данные
- General-Fujitsu ARH45LUAN Сервис мануал
- General-Fujitsu ARH45LUAN Брошюра
- General-Fujitsu ARG60AUAK Сервис мануал
- General-Fujitsu ARG60AUAK Технические данные
- General-Fujitsu ARG60AUAK Брошюра
- General-Fujitsu ARG60RUAK Технические данные
- General-Fujitsu ARG60RUAK Сервис мануал
- General-Fujitsu ARG60RUAK Брошюра