Haier HSU-07RD03 — настройка направления воздушного потока в кондиционере [10/18]
Содержание
- Operation manual p.1
- Split type room air conditioner p.1
- Contents p.2
- Cautions p.3
- Disposal of the old air conditioner p.3
- Disposal of the packaging of your new air conditioner p.3
- Safety instructions and warnings p.3
- Specifications p.4
- The machine is adaptive in following situation p.4
- Cautions p.4
- Outdoor unit p.5
- Indoor unit p.5
- Parts and functions p.5
- Buttons and display of the remote controller p.6
- Operation p.6
- Parts and functions p.6
- Clock set p.6
- Put on the cover again confirmation indicator p.7
- Power failure resume please set and apply as necessary p.7
- Operation p.7
- Loading of the battery p.7
- Load the battery p.7
- Remove the battery cover p.7
- Remote controller s operation p.7
- Operation p.8
- Enjoy yourself by just a gentle press p.8
- Auto run fan operation p.8
- 4 unit stop p.8
- 2 select operation mode p.8
- 1 unit start p.8
- Cool heat and dry operation p.9
- P v a u p.9
- Operation p.9
- Left and right air flow adjustment manual p.10
- Operation p.10
- Cautions p.10
- 6 unit stop p.10
- 5 air flow direction adjustment p.10
- Up and down use remote controller p.10
- To cancel timer mode p.11
- Timer operation p.11
- Timer on off p.11
- Qu q3 0 qq p.11
- Operation p.11
- To cancel timer mode p.12
- Timer on off p.12
- Operation p.12
- 6 time confirming for timer off p.12
- 5 time setting for timer off p.12
- 4 time confirming for timer on p.12
- 3 time setting for timer on p.12
- 2 press timer button to change timer mode p.12
- 1 after unit start select your desired operation mode p.12
- Health mode operation p.13
- Operation p.13
- Emergency operation p.14
- Test operation p.14
- Removal of the restriction of emergency or test operation p.14
- Operation p.14
- Emergency operation and test operation p.14
- Power failure resume function p.15
- Operation p.15
- In heat mode p.15
- In cool mode p.15
- Comfortable sleep p.15
- Cleaning of air filter p.16
- Maintenance p.16
- Cleaning of unit casing p.16
- Cleaning of remote controller p.16
- Better use of air conditioner p.17
- Never fail to observe the followings p.17
- Maintenance p.17
- Trouble shooting p.18
- Before asking for service check the following first p.18
Похожие устройства
-
Haier HSU-24HEK203/R2Эксплуатационная инструкция -
Haier HSU-18HEK203/R2Инструкция по применению -
Haier HSU-12HEK203/R2Эксплуатационная инструкция -
Haier HSU-09HEK203/R2Инструкция по работе -
Haier HSU-07HEK203/R2Руководство по работе с устройством -
Haier HSU-24HEK203/R2(DB)Инструкция по работе -
Haier HSU-18HEK203/R2(DB)Инструкция к устройству -
Haier HSU-12HEK303/R2(DB)Руководство по работе с устройством -
Haier HSU-09HEK303/R2(DB)Руководство по эксплуатации -
Haier AS24NE3HRA/1U24GR4ERAИнструкция к устройству -
Haier AS18ND1HRA/1U18EN2ERAИнструкция пользователя -
Haier AS12NB3HRA/1U12BR4ERAЭксплуатационная инструкция
Operation 5 Air flow direction adjustment After operation mode is selected vertical flap will open automatically according to the mode Up and down Use remote controller Press SWING button vertical flap will move within the range shown in the Fig Press SWING button stop it at a fixed position Left and right air flow adjustment manual Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig About 10 T COOL About 45 HEAT About 60 Cautions Cautions It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode otherwise condensate water might occur When humidity is high condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right 6 Unit stop Cautions Press ON OFF button Unit won t restart until 3 minutes have elapsed due to system protection HEAT mode is not available on cooling only unit Only time remains on LCD All indicators on indoor unit go out Vertical flap closes automatically Hints As cold air flows downward in COOL mode adjusting air flow horizontally will be much more helpful for a better air circulation As warm air flows upward in HEAT mode adjusting air flow downward will be much more helpful for a better air circulation Be careful not to catch a cold when cold air blows downward It is harmful to your health in summer to go frequently in and out of places where temp difference is above 7 C Temp difference of 3 5 C will remove your fatigue More than this unit s load can be reduced and power consumption cut down as well So you d better set a temp diff of 3 5 C between indoor and outdoor temp in COOL mode 8 __
Узнайте, как правильно настроить направление воздушного потока в кондиционере для оптимального охлаждения и обогрева. Следуйте простым инструкциям для лучшего комфорта.
![Haier HSU-12LD03 [10/18] Left and right air flow adjustment manual](/views2/1806497/page10/bga.png)