Haier HSU-07RD03 — emergency and Test Operations for Air Conditioning Systems [14/18]
Содержание
- Operation manual p.1
- Split type room air conditioner p.1
- Contents p.2
- Cautions p.3
- Disposal of the old air conditioner p.3
- Disposal of the packaging of your new air conditioner p.3
- Safety instructions and warnings p.3
- Specifications p.4
- The machine is adaptive in following situation p.4
- Cautions p.4
- Outdoor unit p.5
- Indoor unit p.5
- Parts and functions p.5
- Buttons and display of the remote controller p.6
- Operation p.6
- Parts and functions p.6
- Clock set p.6
- Put on the cover again confirmation indicator p.7
- Power failure resume please set and apply as necessary p.7
- Operation p.7
- Loading of the battery p.7
- Load the battery p.7
- Remove the battery cover p.7
- Remote controller s operation p.7
- Operation p.8
- Enjoy yourself by just a gentle press p.8
- Auto run fan operation p.8
- 4 unit stop p.8
- 2 select operation mode p.8
- 1 unit start p.8
- Cool heat and dry operation p.9
- P v a u p.9
- Operation p.9
- Left and right air flow adjustment manual p.10
- Operation p.10
- Cautions p.10
- 6 unit stop p.10
- 5 air flow direction adjustment p.10
- Up and down use remote controller p.10
- To cancel timer mode p.11
- Timer operation p.11
- Timer on off p.11
- Qu q3 0 qq p.11
- Operation p.11
- To cancel timer mode p.12
- Timer on off p.12
- Operation p.12
- 6 time confirming for timer off p.12
- 5 time setting for timer off p.12
- 4 time confirming for timer on p.12
- 3 time setting for timer on p.12
- 2 press timer button to change timer mode p.12
- 1 after unit start select your desired operation mode p.12
- Health mode operation p.13
- Operation p.13
- Emergency operation p.14
- Test operation p.14
- Removal of the restriction of emergency or test operation p.14
- Operation p.14
- Emergency operation and test operation p.14
- Power failure resume function p.15
- Operation p.15
- In heat mode p.15
- In cool mode p.15
- Comfortable sleep p.15
- Cleaning of air filter p.16
- Maintenance p.16
- Cleaning of unit casing p.16
- Cleaning of remote controller p.16
- Better use of air conditioner p.17
- Never fail to observe the followings p.17
- Maintenance p.17
- Trouble shooting p.18
- Before asking for service check the following first p.18
Похожие устройства
-
Haier HSU-24HEK203/R2Эксплуатационная инструкция -
Haier HSU-18HEK203/R2Инструкция по применению -
Haier HSU-12HEK203/R2Эксплуатационная инструкция -
Haier HSU-09HEK203/R2Инструкция по работе -
Haier HSU-07HEK203/R2Руководство по работе с устройством -
Haier HSU-24HEK203/R2(DB)Инструкция по работе -
Haier HSU-18HEK203/R2(DB)Инструкция к устройству -
Haier HSU-12HEK303/R2(DB)Руководство по работе с устройством -
Haier HSU-09HEK303/R2(DB)Руководство по эксплуатации -
Haier AS24NE3HRA/1U24GR4ERAИнструкция к устройству -
Haier AS18ND1HRA/1U18EN2ERAИнструкция пользователя -
Haier AS12NB3HRA/1U12BR4ERAЭксплуатационная инструкция
Operation Emergency operation and test operation Emergency Operation Carry out this operation only when the remote controller is defective or lost When the emergency operation switch is pressed a Pi sound starts once which means the start of this operation In this operation it is not possible to change the settings of temperature and air flow speed it is also impossible to do an operation by the timer Follow the requirements below Room temperature Designated temperature Timer mode Air flow Operation speed mode More than 23 C 26 C CONTINUOUS AUTO COOL Less than 23 C 23 C CONTINUOUS AUTO HEAT If an air conditioner is a model for both cooling and heating Cooling when the room temperature at the start of operation is above 23 C Heating when the room temperature at the start of operation is below 23 C Test operation Use this switch in the test operation when the room temperature is less 16 C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed setting Hi Removal of the restriction of emergency or test operation Press once more the emergency operation switch or manipulate through the remote controller a Pi sound causes the restriction of emergency or test operation to be removed When the remote controller is manipulated for the removal then the selected operation by the remote controller 12
Learn how to perform emergency and test operations on air conditioning systems. Understand the conditions and settings required for effective operation.
![Haier HSU-07RD03 [14/18] Emergency operation](/views2/1806497/page14/bge.png)