Function
cooling heating
Capacity BTU/h
41000 44000
Capacity kW
12.0 13.0
Sensible heat ratio
70%
W
3700 4000
W 4400
4900
EER or COP
W/W
3.24 3.25
Dehumidifying capacity
10‐³×m³/h
Power cable section
Signal cable section
Connecting cable section
Wired control cable for wired control unit section
//
Power source N, V, Hz
A / A
Start Current A
Class of anti electric shock
CLASS I CLASS I
Circuit breaker A
Max. operating pressure of heat side Mpa
2.8 2.8
Max. operating pressure of cold side Mpa
2.8 2.8
Unit model (color)
Type × Number
Speed(H-M-L) r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Total Area m²
Temp. scope
℃
External
(L×W×H)
mm×mm×mm
Package
(L×W×H)
mm×mm×mm
Air sending angle
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired /model)
Fresh air hole dimension mm
Outlet distribution hole dimension mm
kW
dB(A)
kg / kg
External
(L×W×H)
mm×mm×mm
Package
(L×W×H)
mm×mm×mm
kg / kg
Unit model (color)
Model / Manufacture
Oil model
Oil type
Oil charging
Type
Protection type
Starting method
Type × Number
Speed r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Row / Fin pitch
Temp. scope
℃
External
(L×W×H)
mm×mm×mm
Package
(L×W×H)
mm×mm×mm
Drainage pipe (material , I.D./O.D.) mm
Refrigerant control method mm/mm
Volume of Accumulator L
Noise level dB(A)
material of reduce noise
crankcase heater power W
kg / kg
Type / Charge g
Recharge quantity g/m
Liquid mm
Gas mm
Connecting Method
m
m
Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB
Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level.
The detailed method please refer to the following information:
Flared
Between I.D &O.D
MAX.Drop
30
MAX.Piping length 50
40
Weight (Net / Shipping)
106/111
PIPING
Refrigerant
R22/3400
65
Pipe
φ9.52
φ19.05
59
Type of Four way valve
/
/
Capillary tube
Defrosting
Automatic
/
Dimension
948*340*1250
1090*410*1350
Heat exchanger
inner grooved/φ9.52
2/1.6
Fan
Axial*2
840
0.06
6000
Outdoor unit
HPU-42HV03(WHITE)
Compressor
VR54KS-TFP-542/COPELAND
3GS
1360
SCROLL
Inner thermal protection
hard startup
Weight (Net / Shipping)
59/70
Panel
Dimension
/
/
Weight (Net / Shipping)
/
Electricity Heater /
Noise level (H-M-L)
51
Remote
/
Dimension
1850×600×350
1980×660×420
Indoor unit
HPU-42HV03(WHITE)
Fan
centrifugal
430/405/370
0.09
1750
Heat exchanger
inner grooved/φ7
0.45
Running /Max.Running current
Cooling 6.9A/7.8A Heating 7.0/8.3
50
20
5.0
5G×2.5mm
2
4G×0.75mm
2
3N,380-400V,50HZ
item Model
HPU-42HV03
Total power input
Max. power input
Commercial Air Conditioner Model: HPU-42CV03
HPU-42HV03
Содержание
- Commercial air conditioning 1
- Hpu 42cv03 hpu 42hv03 1
- Service manual 1
- Contents 2
- Brief introduction for t1 t2 t3 working condition 3
- Commercial air conditioner 3
- Description of products features 3
- Operating range of air conditioners 1 operating range of air conditioners 3
- Products code explanation 3
- Central control function if connected with a detector and a central 4
- Commercial air conditioner 4
- Controller 4
- Flexible and easy installation 4
- Malfunction auto checking 4
- Newly designed display panel more simple 4
- Optional safety devices and much more precision control device 4
- Outdoor unit 4
- Powerfull running long distance air sending 4
- Powerfull soft function 4
- Product features 4
- Silent operation 4
- Single fan outdoor more compact 4
- Steady cabinet indoor unit 4
- Commercial air conditioner 5
- Model hpu 42cv03 hpu 42hv03 5
- Specification 5
- Commercial air conditioner 6
- Model hpu 42cv03 hpu 42hv03 6
- Commercial air conditioner 11
- Fixing of the unit 11
- Installation instructions 11
- Installation position 11
- Model hpu 42cv03 hpu 42hv03 11
- Necessary tools 11
- Outdoor unit installation 11
- Commercial air conditioner 23
- Infrared controller functions 23
- Commercial air conditioner 24
- Commercial air conditioner 25
- Commercial air conditioner 26
- Commercial air conditioner 30
- Model hpu 42cv03 hpu 42hv03 30
- Commercial air conditioner 32
- Commercial air conditioner 33
- Model hpu 42cv03 hpu 42hv03 33
- Commercial air conditioner 35
- Commercial air conditioner 36
- Model hpu 42cv03 hpu 42hv03 36
- Commercial air conditioner 42
- Electrical control functions 42
- For indoor unit 1 indoor auto fan control 42
- Automatic run 43
- Commercial air conditioner 43
- Commercial air conditioner 44
- Cool mode control 44
- Dry mode control 44
- Commercial air conditioner 45
- Fan mode control 45
- Heat mode control 45
- Commercial air conditioner 46
- Sleep function 46
- Cabinet v panel off on 47
- Cabinet z panel on off 47
- Commercial air conditioner 47
- Panel selection 47
- Sleep time 1 2 5 8 8 compulsory cooling operation 47
- Sleep time 1 2 8 47
- Style of panel 1 2 47
- System protection 47
- Wired controller on on 47
- Commercial air conditioner 48
- Diagnostic information troubleshooting 48
- Failure code 48
- Commercial air conditioner 49
- Switch 49
- Troubleshooting 49
- Commercial air conditioner 50
- Check if the phase detecting circuit is correct according to ourdoor wiring diagram 51
- Commercial air conditioner 51
- Confirm the malfunction according to the fault code list 51
- If the failure disappear after correcting the wiring 51
- Is fault corrected after sequence of either two of three rst phases is adjusted 51
- Is there phase loss or phase failure 51
- Model hpu 42cv03 hpu 42hv03 51
- No adjust power supply 51
- Phase loss or phase failure 51
- Replace outdoor pcb 51
- Commercial air conditioner 52
- Model hpu 42cv03 hpu 42hv03 52
- Circuit diagram 55
- Commercial air conditioner 55
- For indoor unit 55
- Model hpu 42cv03 hpu 42hv03 55
- Commercial air conditioner 56
- For outdoor unit of hpu 42cv03 56
- Model hpu 42cv03 hpu 42hv03 56
- Commercial air conditioner 57
- Model hpu 42cv03 hpu 42hv03 57
- Commercial air conditioner 58
- For outdoor unit of hpu 42hv03 58
- Model hpu 42cv03 hpu 42hv03 58
- Commercial air conditioner 59
- Model hpu 42cv03 hpu 42hv03 59
- Commercial air conditioner 60
- Printed diagram 60
- Commercial air conditioner 61
- For outdoor unit of hpu 42cv03 61
- Model hpu 42cv03 hpu 42hv03 61
- Commercial air conditioner 62
- For outdoor unit of hpu 42hv03 62
- Model hpu 42cv03 hpu 42hv03 62
- Commercial air conditioner 63
- Model hpu 42cv03 hpu 42hv03 63
- Model part code name characteristic 63
- Sensor characteristic 63
- Commercial air conditioner 64
- Model hpu 42cv03 hpu 42hv03 64
- Commercial air conditioner 65
- Model hpu 42cv03 hpu 42hv03 65
- Haier group 66
- Sincere forever 66
Похожие устройства
- Haier HPU-42HV03 Технические данные
- Haier HPU-42CH03 Инструкция по эксплуатации
- Haier HPU-42CH03 Инструкция по монтажу
- Haier HPU-42CH03 Технические данные
- Haier HPU-42HI03 Руководство по эксплуатации
- Haier HPU-42HI03 Инструкция по монтажу
- Haier HPU-42HI03 Технические данные
- Haier HPU-18C03VA(ZXF) Инструкция по монтажу
- Haier HPU-18C03VA(ZXF) Руководство по эксплуатации
- Haier HPU-24C03/VA(ZXF) Инструкция по монтажу
- Haier HPU-24C03/VA(ZXF) Руководство по эксплуатации
- Haier HSU-22LV03 Инструкция по монтажу
- Haier HSU-22LV03 Инструкция по эксплуатации
- Haier HSU-22LV03 Сервис мануал
- Haier HSU-09LV03 Инструкция по монтажу
- Haier HSU-09LV03 Инструкция по эксплуатации
- Haier HSU-09LV03 Сервис мануал
- Haier HSU-12LV03 Инструкция по монтажу
- Haier HSU-12LV03 Инструкция по эксплуатации
- Haier HSU-12LV03 Сервис мануал