1.
local wiring satandard.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person.The type of connecting wire is H05RN-F,(4G 1.5mm )
The type of power wire is H05RN-F,(3G 2.5mm ).
The distance between its two terminal blocks of indoor unit and the outdoor unit should
not be over 5m.If exceeded,the diameter of the wire should be widen according to the
2
2
5
5.Easily-demount cleaning of indoor unit
1.Top inlet can be taken down
Open the inlet grille, press the claw of the clip on the unit,then
take down the top inlet.(according to figure 1)
claw of the clip
Figure 1
Figure 2
Figure 3
2.Vertical flap can be taken down
Overturn the vertical flap, press the claw of the clip ,then take
down vertical flap.(according to figure 2)
3.Horizontal louvers can be taken down
After taking down vertical flap.Horizontal louvers are appeared,draw
the middle louver,and take down the horizontal louvers .
(according to figure 3)
Figure 2
Daff
In
123
WB R
Y/G
Y/G
LN
WB
Y/G
door unit
Power supply
Outdoor unit
Y/G
123
WB R
Y/G
Y/G
2.
3.
If the fuse on PC board is broken please change it with the type of T3.15/250VAC.
The wiring method should be in line with the local wiring standard.
The earth line should be security connected.
4.