Haier 1U36LP2VHA [30/42] English

Содержание

WIRED CONTROLLER INSTALLATION ENGLISH Wired Controller Wiring Instructions The communication wiring is 189ft 4 8 meter long if the actual length is more than it please distribute wiring according to below table Step By Step Guide To Installation A TYPE 1 FOR AL24 36 42 48LP2VHA AM24LP2VHA Communication Wiring Communication Wiring length TYPE 2 FOR AM36 42 48LP2VHA Dimension of Wiring 0 100 ft 0 30m 22AWG 0 3mm2 x3 core shielded wire 100 200 ft 30 60m 20AWG 0 5mm2 x3 core shielded wire 200 300 ft 0 90m 18AWG 0 75mm2 x3 core shielded wire 300 400 ft 90 120m 16AWG 1 25mm2 x3 coreshielded wire One side of the shielded sheet of communication wire must be earthed Press this button to open the back There are three methods to connection wire controller and the indoor units A One wired controller can control max up to 16 sets of indoor units for Flexifit Pro series indoor units there are two connection method Type 1 for model AL24 36 42 48LP2VHA AM24LP2VHA the wiring connection between wired controller the master unit directly connected to the wired controller master unit slave unit slave unit slave unit should be one to one match of all three lines Type 2 for model AM36 42 48LP2VHA The wiring connection between wired controller the master unit directly connected to the wired controller should be three polar wire and the wiring between master unit slave unit slave unit slave unit should be one to one match of two polar lines Put communication wire through the hole in the back cover as shown Mount the back cover in the desired location making sure not to pinch the communication wire Then connect the communication wire to CON1 port of the wired controller Replac Note PCB DIP switches are used for setting slave units please refer to indoor unit wiring diagram B One wire controller controls one indoor unit and the indoor unit connects with the wire controller through 3 pieces of polar wire C Two wired controllers control one indoor unit The wire controller connected with indoor unit is called master one the other is called slave one Master wire controller and indoor unit master and slave wire controllers are all connected through 3 pieces of polar wire Note There are PCB DIP switches for slave or master units selection please refer to the indoor unit wiring diagram to get details About the wire The wire controller is equipped with special communication wiring in the accessories 3 core terminal 1 white 2 yellow 3red is connected with the terminal A B C of wire controller respectively PAGE30 REMOTE CONTROLS

Скачать