Haier HC18-60C1VAR [5/17] Figure 1
![Haier HC18-60C1VAR [5/17] Figure 1](/views2/1820071/page5/bg5.png)
Figure 1
Minimum Circuit Amps
15 25 25 30 40 35 40 60 60
Rated Load Amps 7.4 9.6 11.8 13.0 16.7 15.8 18.7 26.6 28.9
Compressor Locked Running
Amps 48 60 73 85 105 90 135 155 165
Full Load Amps 0.86 1.4 1.4 1.43 1.43 1.43 1.43
Fan Motor Rated HP 1/8 1/5 1/5 1/3 1/3 1/3 1/3
Nominal RPM 850 1075 1075 1075 1075 1075 1075
Liquid Line OD - In (mm) 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8" [9.52] 3/8"[9.52] 3/8"[9.52]
Vapor Line OD - In (mm) 5/8"[15.88] 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2]
R-22 Charge -Oz (g) 74.2 [2100] 91.87[2600] 88.34[2500] 102.47[2900] 132.51[3750] 125.44[3550]
Net Dimensions - In (mm) 23*23*27 3/4 23*23*27 3/4 23*23*31 1/2 30 1/4*30 1/4*27 3/4 30 1/4*30 1/4*35 1/2 301/4*30 1/4*35 1/2 30 1/4*30 1/4*31 1/2
W*D*H [585* 585*705] [585* 585*705] [585* 585*805] [770 *770*705] [770 *770*905] [770 *770*905] [ 770 *770*805]
Shipping Dimensions - In (mm) 25*25*32 1/4 25*25*32 1/4 25*25*36 32 3/4*32 3/4*32 1/2 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*36
W*D*H [632* 632*819] [632* 632*819] [632* 632*919] [832*832*830] [832*832*1030] [832*832*1030] [832* 832*930]
Net Weight - Lbs (kg) 123[56] 125[57] 139[63] 196[89] 231[105] 238[108] 298[135]
Approx Shipping Weight - Lbs (kg) 141[64] 143[65] 152[69] 222[101] 257 [117] 264[120] 321[146]
183.75[5200]
The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical
specifications are provided in Table 3 for 12 SEER systems respectively.
3
H
W
D
Table 2:System Cooling Capacity
Outdoor Unit With This Indoor Air handler
Model Number
HC18A1VAR HB2400VA1M20
HC24A1VAR HB2400VA1M20
HC30A1VAR HB3000VA1M20
HC36A1VAS HB3600VA1M20
HC42A1VAR HB4200VA1M25
HC48A1VAR HB4800VA1M25
HC60A1VAR HB6000VA1M25
Air Handler
Cooling Capacity (Btu/h) SEER Rated
Sensible Total CFM(Outdoor)
13000
17000
20000
24000
1850
1850
1950
1950
18000
24000
28000
34000
10
10
10
10
28400
29160
33120
2700
2700
2900
40000
40500
46000
10
10
10
33120
40170
40180
2900
2900
2900
46000
55800
56000
10
10
10
Compressor
brand
Bristol
Bristol
Bristol
Bristol
Bristol
Bristol
Bristol
Sanyo
Sanyo
Sanyo
H23R
H20R
H29A H23R
H29A
H20J
28.8
145
2.5
60
1/2
171.38[4850]
120.14[3400] 127.21[3600]
Model:HC18-60C1VAR
Table 3:
MODEL: HC18C1VAR HC24C1VAR HC30C1VAR HC36C1VAR HC42C1VAR HC48C1VAR HC60C1VAR
Unit Supply Voltage
Normal Voltage Range
208/230-1-60
197 - 253
Compressor Brand
Bristol
Bristol
10.1 13.4 16.2 17.7 22.3 21.2
34.724.8 37.6 38.5
Max Fuse or Max CKT. BKR.
(HACR per NEC )
Содержание
- Central air conditioner 1
- Installation operation manual 1
- Warning 2
- Introduction 3
- Nomenclature for model number 3
- Table of content 3
- Model hc18 60a1var s 4
- Specification 4
- Table 1 4
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 1 for 10 seer systems respectively 4
- Figure 1 5
- Model hc18 60c1var table 3 5
- Table 2 system cooling capacity 5
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 3 for 12 seer systems respectively 5
- Model hc18 60d1var 6
- Table 4 system cooling capacity 6
- Table 5 6
- Table 6 system cooling capacity 6
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 5 for 13 seer systems respectively 6
- Equipment protection from environment 7
- Installation 7
- Unit inspection 7
- Do not allow the vapor line and liquid line to touch together this would cause an undesirable heat transfer resulting in capacity loss and increased power consumption 9
- Figure 3 9
- Line insulation suction line requires insulation in order to prevent condensation from forming on the piping and to prevent heat gain caused by surrounding air generally 3 8 wall thickness of armflex or equivalent is satisfactory in severe application hot high humidity areas greater thickness may be required apply the line insulation by sliding it on the sealed tuing before cutting and making connections 9
- Liquid line does not necessarily need insulation however if they are exposed to high ambient temperatures i e kitchen boiler rooms hot attics rooftop surface then they should be insulated make sure to use the proper size tubing for the liquid line to prevent liquid refrigerant flashing to a vapor within the liquid line 9
- Electrical wiring 12
- System startup 13
- Miscellaneous 14
- Operation 14
- Air conditioner wi ring diagram 16
- Br brown gr green or orange 16
- Color codes bk black bl blue gy gray 16
- Component codes bcr blower control relay bcap run capacitor blower motor cc compressor contactor cch crankcase heater optional chs crankcase heater switch optional cmpr compressor hps high pressure switch lps low pressure switch ibm indoor blower motor ofm outdoor fan motor rcap run capacitor compressor rvs reversing valve solenoid stcap start capa citor optional strly start relay optional strth start thermistor optional tran transformer 230 208 selectable 16
- Compress or protect 3 min time delay 16
- Compressor 16
- Ha cool off heat 16
- Hc18 60a1var s hc18 60c1var hc18 60d1var 16
- Line volta ge factory standard field installed optional low voltage factory standard field installed optional 16
- Optional low high pressur e switches 16
- Pu purple rd red vi violet 16
- Use copper conductors only warning cabinet must be permanently grounded and all wiring to conform to i e c n e c c e c c l c and local codes as applicable replacement wire must be the same gage and insulation type as original wire 16
- Vac common 16
- Wh white yl yellow 16
Похожие устройства
- Haier HC18-60D1VAR Инструкция по эксплуатации
- Haier HSU-09RK03/R2(SDB) Инструкция по эксплуатации
- Haier HDU-42HT03/H Инструкция по эксплуатации
- Haier HSU-09H03/K(F) Инструкция по монтажу
- Haier HSU-12H03/K(F) Инструкция по монтажу
- Haier HSU-12C03/K(F) Инструкция по монтажу
- Haier HSU-09HG13-B Инструкция по монтажу
- Haier HSU-12HG13-B Инструкция по монтажу
- Haier HSU-12HEA03/(BP) Инструкция по эксплуатации
- Haier HSU-12C03K Инструкция по монтажу
- Haier HPRD12XC5 Инструкция по эксплуатации
- Haier HPRD12HC5 Инструкция по эксплуатации
- Haier HSU-09RF03/R2 Инструкция по эксплуатации
- Haier HSU-12RF03/R2 Инструкция по эксплуатации
- Haier HSU-07HC03/R2 Инструкция по эксплуатации
- Haier HSU-09HC03/R2 Инструкция по эксплуатации
- Haier HSU-12HC03/R2 Инструкция по эксплуатации
- Haier HSU-07HE03/R2 Инструкция по эксплуатации
- Thermona THERM 18 EZ/B Инструкция по эксплуатации
- Thermona THERM 18 EZ/B Проектная документация