Haier HC18-60C1VAR [6/17] Table 4 system cooling capacity
![Haier HC18-60C1VAR [6/17] Table 4 system cooling capacity](/views2/1820071/page6/bg6.png)
4
Outdoor Unit With This Indoor Air handler
Model Number
HC18C1VAR HB2400VC1M20
HC24C1VAR HB2400VC1M20
HC30C1VAR HB3600VA1M20
HC36C1VAR HB3600VC1M25
HC42C1VAR HB4800VA1M25
HC48C1VAR HB4800VA1M25
HC60C1VAR HB6000VC1M25
41800
2900
58000
12
Bristol
Table 4:System Cooling Capacity
Air Handler
Cooling Capacity (Btu/h) SEER Rated
Sensible Total CFM(Outdoor)
14820
18720
23400
25920
1950
1950
1950
2700
19000
24000
30000
36000
12
12
12
12
30240
34560
2900
2900
42000
48000
12
12
Compressor
brand
Bristol
Bristol
Bristol
Bristol
Bristol
Bristol
15 20 20 25 30 35 55
Rated Load Amps 6.2 8.6 9.2 11.7 13.0 15.8 25.0
Compressor Locked Running
Amps 41 60 60 73 85 90 150
Full Load Amps 0.86 0.86 0.86 1.3 1.43 2.0 2.0
Fan Motor Rated HP 1/8 1/6 1/6 1/4 1/3 1/3 1/3
Nominal RPM 1000 840 840 850 1075 960 880
Liquid Line OD - In (mm) 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8" [9.52] 3/8"[9.52] 3/8"[9.52]
Vapor Line OD - In (mm) 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2]
R-22 Charge -Oz (g) 93.64[2650] 102.47[2900] 121.91[3450] 134.28[3800] 148.41[4200] 178.45[5050] 196.11[5550]
Net Dimensions - In (mm) 23*23*31 1/2 30 1/4*30 1/4*27 3/4 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*35 1/2 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*35 1/2
W*D*H
[585* 585*805]
[770* 770*705]
[770* 770*805]
[770 *770*805] [770 *770*905] [770 *770*805] [ 770 *770*905]
Shipping Dimensions - In (mm) 24 3/4*24 3/4*36 32 3/4*32 3/4*32 1/2 32 3/4*32 3/4*36 32 3/4*32 3/4*36 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*36 32 3/4*32 3/4*40 1/2
W*D*H
[632* 632*919]
[832* 832*830]
[
832* 832*930]
[832*832*930] [832*832*1030] [832*832*930] [832*832*1030]
Net Weight - Lbs (kg) 156[71] 194[88] 198[90] 203[92] 231[105] 244[111] 258[117]
Approx Shipping Weight - Lbs (kg) 167[76] 209[95] 216[98] 220[100] 249 [113] 262[119] 282[128]
The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical
specifications are provided in Table 5 for 13 SEER systems respectively.
Model:HC18-60D1VAR
Outdoor Unit With This Indoor Air handler
Model Number
HC18D1VAR HB2400VD1M20
HC24D1VAR HB2400VD1M20
HC30D1VAR HB3600VD1M22
HC36D1VAR HB3600VD1M22
HC42D1VAR HB4800VD1M22
HC48D1VAR HB4800VD1M22
HC60D1VAR HB6000VD1M22
40700
4000
55000
13
Bristol
Table 6:System Cooling Capacity
Air Handler
Cooling Capacity (Btu/h) SEER Rated
Sensible Total CFM(Outdoor)
13300
17700
20669
25900
1350.0
1800.0
2100
2700
18000
24000
28000
35000
13
13
13
13
29600
34800
3200
3600
40000
47000
13
13
Compressor
brand
Bristol
Bristol
Bristol
Bristol
Bristol
Bristol
Table 5:
MODEL: HC18D1VAR HC24D1VAR HC30D1VAR HC36D1VAR HC42D1VAR HC48D1VAR HC60D1VAR
Unit Supply Voltage
Normal Voltage Range
Compressor Brand
Minimum Circuit Amps
208/230-1-60
197 - 253
Bristol
8.6 11.6 12.4 15.9
17.7 21.8 33.3
Max Fuse or Max CKT. BKR.
(HACR per NEC )
Содержание
- Central air conditioner 1
- Installation operation manual 1
- Warning 2
- Introduction 3
- Nomenclature for model number 3
- Table of content 3
- Model hc18 60a1var s 4
- Specification 4
- Table 1 4
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 1 for 10 seer systems respectively 4
- Figure 1 5
- Model hc18 60c1var table 3 5
- Table 2 system cooling capacity 5
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 3 for 12 seer systems respectively 5
- Model hc18 60d1var 6
- Table 4 system cooling capacity 6
- Table 5 6
- Table 6 system cooling capacity 6
- The dimensions for the condensing unit are illustrated in figure 1 physical and electrical specifications are provided in table 5 for 13 seer systems respectively 6
- Equipment protection from environment 7
- Installation 7
- Unit inspection 7
- Do not allow the vapor line and liquid line to touch together this would cause an undesirable heat transfer resulting in capacity loss and increased power consumption 9
- Figure 3 9
- Line insulation suction line requires insulation in order to prevent condensation from forming on the piping and to prevent heat gain caused by surrounding air generally 3 8 wall thickness of armflex or equivalent is satisfactory in severe application hot high humidity areas greater thickness may be required apply the line insulation by sliding it on the sealed tuing before cutting and making connections 9
- Liquid line does not necessarily need insulation however if they are exposed to high ambient temperatures i e kitchen boiler rooms hot attics rooftop surface then they should be insulated make sure to use the proper size tubing for the liquid line to prevent liquid refrigerant flashing to a vapor within the liquid line 9
- Electrical wiring 12
- System startup 13
- Miscellaneous 14
- Operation 14
- Air conditioner wi ring diagram 16
- Br brown gr green or orange 16
- Color codes bk black bl blue gy gray 16
- Component codes bcr blower control relay bcap run capacitor blower motor cc compressor contactor cch crankcase heater optional chs crankcase heater switch optional cmpr compressor hps high pressure switch lps low pressure switch ibm indoor blower motor ofm outdoor fan motor rcap run capacitor compressor rvs reversing valve solenoid stcap start capa citor optional strly start relay optional strth start thermistor optional tran transformer 230 208 selectable 16
- Compress or protect 3 min time delay 16
- Compressor 16
- Ha cool off heat 16
- Hc18 60a1var s hc18 60c1var hc18 60d1var 16
- Line volta ge factory standard field installed optional low voltage factory standard field installed optional 16
- Optional low high pressur e switches 16
- Pu purple rd red vi violet 16
- Use copper conductors only warning cabinet must be permanently grounded and all wiring to conform to i e c n e c c e c c l c and local codes as applicable replacement wire must be the same gage and insulation type as original wire 16
- Vac common 16
- Wh white yl yellow 16
Похожие устройства
- Haier HC18-60D1VAR Инструкция по эксплуатации
- Haier HSU-09RK03/R2(SDB) Инструкция по эксплуатации
- Haier HDU-42HT03/H Инструкция по эксплуатации
- Haier HSU-09H03/K(F) Инструкция по монтажу
- Haier HSU-12H03/K(F) Инструкция по монтажу
- Haier HSU-12C03/K(F) Инструкция по монтажу
- Haier HSU-09HG13-B Инструкция по монтажу
- Haier HSU-12HG13-B Инструкция по монтажу
- Haier HSU-12HEA03/(BP) Инструкция по эксплуатации
- Haier HSU-12C03K Инструкция по монтажу
- Haier HPRD12XC5 Инструкция по эксплуатации
- Haier HPRD12HC5 Инструкция по эксплуатации
- Haier HSU-09RF03/R2 Инструкция по эксплуатации
- Haier HSU-12RF03/R2 Инструкция по эксплуатации
- Haier HSU-07HC03/R2 Инструкция по эксплуатации
- Haier HSU-09HC03/R2 Инструкция по эксплуатации
- Haier HSU-12HC03/R2 Инструкция по эксплуатации
- Haier HSU-07HE03/R2 Инструкция по эксплуатации
- Thermona THERM 18 EZ/B Инструкция по эксплуатации
- Thermona THERM 18 EZ/B Проектная документация