Haier AB142ACBJA [4/27] Cautions
![Haier AB142ACBJA [4/27] Cautions](/views2/1822211/page4/bg4.png)
2
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
AB142/182ACBFA:
Other Instructions
*****
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken, please
change it with the type of T3.15A /250VAC.
4. Use copper wire only. The connecting cable
should be H05RN-F 3G(2.5mm
2
+H05RN-F
1x 0.75mm
2
. The power cable should be
H05RN-F 3G 2.5mm
2
.All the cables shall
have got the European authentication certificate.
***************
AB092/122ACBJA AB142/182ACBJA:
051220*********
1. The waste battery should be disposed properly.
When throw away the waste batteries, please
perform in accordance with the local regulation.
2. The indoor unit installation height is at least
2.5m.certificate.
5. The power cord should be self-provided and
it should have got the Local authentication
certificate.
6. The air breaker should be all-pole switch.
and the distance between it's two
connecters should no less than 3mm.
7. Air conditioner must use special power supply
system (above 20A), and qualified electrician
makes wiring and fixing according to wiring
regulations specified in national standard.
8. In socket, exactly distinguish earth wire with
neutral wire and it is wrong to connect them
together.
9. A leakage breaker must be installed.
10. Connection method is Y-connection .If the
power cord is damaged, it must be replaced
by professional people of manufacturer or its
maintenance department or similar to avoid
dangers.
11. The air breaker and the power switch should
installed the conveniently reachable place for
user.
AB142ACBFA AB182ACBFA:
Attention:
As a result of poor conditions of the electrical
MAINS, shortly voltage drops can appear
when starting the EQUIPMENT. This can
influence other equipment (et.Blinking of a
lamp). If the MAIN-IMPEDANCE Zmax<
0.3970617HM, such disturbance are not
expected. In case of need , you may contact
your local supply authority for further
information.
Содержание
- Cassette type air conditioner 1
- Operation installation manual 1
- Cassette type air conditioner 2
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Specifications 4
- Diferent fan speed 5
- Main points of operation 5
- Minute protection function 5
- Operation of air conditioner 5
- Remote control 5
- Anti cold blowing off 6
- Auto restant function to be applied for a necessary situation 6
- Defrosting function 6
- In heating mode the indoor fan will not run immediately after the unit starts up which will the cold air being blow out 6
- In heating mode when frost is formed on the outdoor heat exchanger the air conditioner will automatically defrost for few minutes during defrosting both indoor fan and outdoor fan will stop running when defrosting finishes air condi tioner will automatically be back to running 6
- Main points of operation 6
- The air conditioner absorbs heat form outdoor and releases to indoor when in heating mode therefore the outdoor environmental temperature will affect heating efficiency 6
- Air filter 7
- Air inlet grille 7
- Indoor unit 7
- Operating control panel 7
- Outdoor unit 7
- Part name 7
- Remote receiver compressor lamp timer lamp operation lamp power lamp emergency switch 7
- Swing louver 7
- Be sure to conform with the following important safety precautions the safety precautions should be at hand so that they can be checked at any time when necessary if the air conditoner is transferred to the new user this manual should be as well transferred to the new user 8
- Below are listed four kinds of safety precautions and suggestions 8
- Carefully read the following information in order to operate the air conditioner correctly 8
- Caution 8
- Incorrect operations may result in injures or machine damages in some cases may cause serious consequences 8
- Incorrect operations may result in severe consequences of death or serious injures 8
- Instruction 8
- It must be strictly prohibited where being marked with ì prohibited î otherwise may result in machine damages or endanger the usersípersonal safety 8
- Safety precautions 8
- This information can ensure the correct operation of the machine 8
- Warning 8
- Safety precautions 9
- Warning 9
- Caution 10
- Clean indoor outdoor unit 10
- Clean the air filter 10
- Clean the unit 10
- Maintenance 10
- Take down air inlet grille 10
- Take down the filter 10
- Maintenance 11
- Post season care 11
- Pre season care 11
- Seasonal reserve 11
- Cold air blown out when heating 12
- Insufficient cooling 12
- Insufficient cooling or heating 12
- When trouble happens 12
- Customer need to know 13
- Using directions 13
- Installation tools 14
- Installation preparation 15
- Installation procedures 15
- Selection of installation place 15
- After installation on the ceiling 16
- In case of no ceiling 16
- In the case of existing ceiling 16
- Installation of indoor unit 16
- Installation procedures 16
- Cautions for the water drainage lifting pipe 17
- Installation of water drainage pipe 17
- Installation procedures 17
- Install ornament panel on indoor unit 18
- Installation of ornament panel 18
- Installation procedures 18
- Panel limitation board installation 18
- Piping connection 18
- 092 122 19
- Cautions for piping connection 19
- Installation procedures 19
- 4 purging method the refrigerant is r407c 20
- Installation procedures 20
- To use vacuum pump 20
- Connection of outdoor piping 21
- Crimp connection method of connecting line 21
- Electrical wiring 21
- Installation fixing 21
- Installation of drain elbow 21
- Installation procedures 21
- Wiring connection 21
- Wiring method of straight terminal 21
- Wiring methods 1 wiring method of ring terminal 21
- Wiring of indoor unit 21
- Installation procedures 22
- Wiring connection 22
- The followings are not malfuncition 23
- Troubleshooting 23
- Please check the following things about your air conditioner before making a service call 24
- Troubleshooting 24
- Unit fails to start 24
- Failure code 25
- Check and test run 26
- Installation check and test run 26
Похожие устройства
- Haier AB182ACBJA Инструкция по эксплуатации
- Haier AB142ACBFA Инструкция по эксплуатации
- Haier AB182ACBFA Инструкция по эксплуатации
- Haier AB182ACAEA Инструкция по эксплуатации
- Haier AB282ACAEA Инструкция по эксплуатации
- Haier AB42NACAEA Инструкция по эксплуатации
- Vodotok НСП-600 Инструкция по эксплуатации
- Vodotok НСП-800 Инструкция по эксплуатации
- Vodotok PJm80 Инструкция по эксплуатации
- Vodotok PJm100 Инструкция по эксплуатации
- Vodotok PJWm10H Инструкция по эксплуатации
- Vodotok PJWm15H Инструкция по эксплуатации
- Vodotok XRS20/4-130 Инструкция по эксплуатации
- Vodotok XRS25/4-130 Инструкция по эксплуатации
- Vodotok XRS25/4-180 Инструкция по эксплуатации
- Vodotok XRS32/4-180 Инструкция по эксплуатации
- Vodotok XRS20/6-130 Инструкция по эксплуатации
- Vodotok XRS25/6-130 Инструкция по эксплуатации
- Vodotok XRS25/6-180 Инструкция по эксплуатации
- Vodotok XRS32/6-180 Инструкция по эксплуатации