Haier AS182ATAHA [7/18] Cautions

Содержание

Indoor Unit Cautions When connecting the cable after installing the indoor unit 1 Insert from outside the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop Safety Instruction Please read the following Safety Instructions carefully prior to use t When connecting the cable before installing the indoor unit Insert the cord from the back side of the unit then pull it out on the front side Loosen the screws and insert the cord ends fully into terminal block then tighten the screws Pull the cable slightly to make sure the cord have been properly inserted and tightened After the cord connection never fail to fasten the connected cord with the wiring cover Note When connecting the cord confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect The instructions are classified into two levels WARNING and CAUTION according to the seriousness of possible risks and damages as follows Compliance to the instructions are strictly required for safety use Installation WARNING Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage Installation in a inadequate place may cause accidents Do not install in the following place CAUTION Connect the earth Do not install in the Do not get the unit Check proper cable place where there exposed to vapor installation of the is any possibility or oil steam drainage securely of inflammable gas leakage around the unit Q Q PROHIBITION 28 PROHIBITION 5