Haier AS182ATAHA [8/18] Parts and functions
Содержание
- Inverter room air conditioner 1
- Operation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Cautions 4
- Check for installation and test run 4
- Cutting and flaring work of piping 4
- On drainage 4
- Outdoor unit 4
- Power source installation 4
- A caution 5
- Cautions 5
- Connecting the earthing cable 5
- Do not block the air inlet or outlet 5
- Outdoor unit 5
- Plug in 5
- Purgeing method 5
- Cautions 6
- Outdoor unit 6
- Use of air conditioner 6
- Caution 7
- Cautions 7
- Indoor unit 7
- Installation 7
- Safety instruction 7
- Warning 7
- Drawing of pipe 8
- Fixing the indoor unit body 8
- Indoor unit 8
- Indoor unit outdoor unit 8
- Parts and functions 8
- Removing the wiring cover 8
- Indoor unit 9
- Parts and functions 9
- Remote controller 9
- When the mounting plate is first fixed 9
- When the mounting plate is fixed to side bar and lintel 9
- When the paper pattern is used 9
- Attach the lid 10
- Handling the wireless remote controller 10
- Indoor unit 10
- Insert the dry batteries 10
- Inserting dry batteries 10
- Outdoor unit 10
- Parts and functions 10
- Power source 10
- Remove the lid 10
- Selection of installation placeon of inst 10
- Selection of pipe 10
- Two r 03 dry batteries 10
- Verify by the indicators 10
- Fixing of outdoor unit 11
- Health mode operation 11
- Operation 11
- Cool heat and dry operation 12
- Installation manual of room air conditioner 12
- Operation 12
- Air flow direction adjustment 13
- Cautions 13
- Left and right air flow adjustment manual 13
- Trouble shooting operation 13
- Unit stop 13
- Up and down use remote controller 13
- When a trouble or abnormality occurred with the machine 13
- X note 13
- Caution 14
- Operation trouble shooting 14
- Power mode operation 14
- Super mode operation 14
- Maintenance operation 15
- Soft mode operation 15
- To keep you air conditioner in good condition power mode operation 15
- A caution 16
- Changing the designated period 16
- Inlet grill cleaning 16
- Maintenance 16
- Off timer function 16
- Operation 16
- Timer cancellation 16
- Timer function usage 16
- A warning 17
- For smart use of the air conditioner timer function usage 17
- Maintenance operation 17
- On timer function 17
- Close doors and windows 18
- Do not block the air inlet 18
- During operation 18
- Emergency and test operation for smart use of the air conditioner 18
- Emergency operation 18
- For a long time turn off the 18
- If the unit is not to be used 18
- Operation maintenance 18
- Or outlet 18
- Power supply main switch 18
- Setting of proper room 18
- Temperature 18
- Termination of emergency or test operation 18
- Test operation 18
- Use the louvers effectively 18
Похожие устройства
- Haier HSU-18H03(B) Инструкция по эксплуатации
- Haier HSU-18HB03(B) Инструкция по эксплуатации
- Haier AU182AFAHA Инструкция по эксплуатации
- Haier AU182AFAEA Инструкция по эксплуатации
- Haier AU182AFMFA Инструкция по эксплуатации
- Haier AU282AHAFA Инструкция по эксплуатации
- Haier AP182AKAAA Инструкция по эксплуатации
- Haier AP182AZAAA Инструкция по эксплуатации
- AnyTone AT-310M Инструкция по эксплуатации
- AOR AR-3000A Инструкция по эксплуатации
- Baofeng BF-T3 Инструкция по эксплуатации
- Baofeng KS-315 Инструкция по эксплуатации
- Baofeng Mini 1 Инструкция по эксплуатации
- Baofeng UV-5R 3800 Инструкция по эксплуатации
- BFDX BF-RT7500 Инструкция по эксплуатации
- CB TTI ТСВ-775 Инструкция по эксплуатации
- Codan NGT SRx Инструкция по эксплуатации
- Comet CAA-500 Mark II Инструкция по эксплуатации
- FlightLine FL-M1000E Инструкция по эксплуатации
- Yaesu FT-4Xr Инструкция по эксплуатации
PARTS AND FUNCTIONS outdoor unit Indoor unit CONNECTING PIPING AND ELECTRICAL WIRING Indoor Unit 3 Installation of the Indoor Unit Drawing of pipe Rear piping Draw pipes and the drain hose then fasten them with the adhesive tape Left Left rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cord from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure fixing with adhesive tape Fix with adhesive tape The machine is adaptive in following situation Indoor outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape 1 Applicable ambient temperature range Indoor Cooling Oudoor Indoor Heating Oudoor Maximum D B W B Minimum D B W B Maximum D B Minimum D B Maximum D B Minimum D B Maximum D B W B Minimum D B W B 32 C 23 C 18 C 14 C 43 C 15 C 27 C 20 C 24 C 18 C 7 C 8 C 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent one similar qualified person The type of connecting wire is H05RN F or H07RN F Cooling Heating Other direction piping Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole When bending be careful not to crash pipes Connect beforehand the indoor outdoor electric cable and then pull out the connected to the heat insulation of connecting part specially Fixing the indoor unit body Hang surely the unit body onto the upper notches of the unting plate Move the body from side to side toverify its secure fixing In order to fix the body onto the mounting plate hold up the body aslant from the underside and then put it down perpendicularly 3 G 2 5 mm2 1 x 0 75 mm2 3 If the fuse on PC board is broken please change it with the type of T 3 15A 250V 4 The distance between the indoor unit and the floor should be more than 2 0m 5 The wiring method should be in line with the local wiring standard 6 After installation the power plug should be easily reached 7 The waste battery should be disposed properly 8 The appliance is not intended for use by young children or infirm persons without supervision 9 Young children should be supervised to ensure that they do not play with the appliance 1O The requirement of the power supply cord H05RN 3G2 5mm2 Suitable for installation in European region 6 4 Connecting the indoor Outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws 27