Haier AB0142ACERA [6/27] H main points of operation

Содержание

H Main points of Operation Prevent Cool Air Blowing Off In heating mode the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off Defrosting Function In heating mode when frost formed on the outdoor heat exchanger the air conditioner will automatically defrost a few minutes During defrosting both indoor and outdoor fan will stop running When defrosting finished air condi tioner will automatically back to running Defrosting Running Hints The air conditioner absorbs heat form outside and releases inside when in heating mode therefore the outside environmental temperature will affect heating effects Power Failure Compensation to be applied for a necessary situation After the power failure compensation is set if power failure suddenly occurs while the air conditioner is working it will resume the previous working state when the power is supplied again Setting Method When the remote controller is on excluding timer mode and fan mode press the sleeping button on the remote controller 10 times within 5 seconds and after the buzzer rings 4 times the air conditioner will enter the state of power failure compenstation Cancel Method Press the sleeping button on the remote controller 10 times within 5 seconds and after the buzzer rings 2 times the power failure compensation mode will be cancelled Note When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set if the air conditioner will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the Switch On Off button after the power comes again 4