DM13-01.01.12en Neola Inverter
Service manual 11
3. Specification
Indoor MS11D-09HRDN1 MS11D-12HRDN1
Outdoor MO11D-09HDN1 MO11D-12HDN1
Power supply Ph-V-Hz 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph
Cooling
Capacity
Btu/h 9000(2250~10500) 12000(2450~14500)
kW 2,64 (0,66~3,08) 3,52 (0,72~4,25)
Input W 815(180~1100) 1090(210~1380)
Rated current A 3.6(0.9~4.8) 4.8(1.0~6.2)
EER W/W 3.21 3.22
Heating
Capacity
Btu/h 10000(2300~11500) 13500(2800~17000)
kW 2,93 (0,67~3,37) 3,96 (0,82~4,98)
Input W 810(170~1050) 1090(210~1480)
Rated current A 3.6(0.8~4.6) 4.9(1.0~6.6)
COP W/W 3.62 3.63
Moisture Removal L/h 1.0 1.2
Max. input consumption W 1695 2040
Max. current A 7.7 9.4
Starting current A ---- ----
Compressor
Model DA108X1C-23EZ DA108X1C-23EZ
Type ROTARY ROTARY
Brand TOSHIBA TOSHIBA
Capacity Btu/h 11021 11021
Input W 855 855
Rated current(RLA) A 4.95 4.95
Locked rotor Amp(LRA) A ---- ----
Thermal protector ---- ----
Thermal protector position ---- ----
Capacitor uF 6.0 6.0
Refrigerant oil/oil charge ml ESTER OIL VG74 480ml ESTER OIL VG74 480ml
Indoor fan motor
Model RPG13H RPG20D
Brand Welling Welling
Input W 34 43.3
Capacitor uF 1.2 1.5
Speed(Hi/Mi/Lo) r/min 1100/900/800 1200/1050/800
Indoor coil
a.Number of rows 1/2 1/2
b.Tube pitch(a)x row
pitch(b)
mm 20x11.28 21x13.37
c.Fin spacing mm 1.3/1.4 1.2/1.3
d.Fin type (code) Hydrophilic aluminium Hydrophilic aluminium
e.Tube outside dia.and
type
mm φ6,innergroove tube Φ7,innergroove tube
Содержание
- Neola inverter series 1
- Contents 2
- Installation 3
- Precaution 3
- Safety precaution 3
- Warning 3
- Caution 5
- Operational 6
- Function 8
- Model names of indoor outdoor units 8
- Ms11d 24hrdn1 mo11d 24hrdn1 8
- Dm13 01 1 2en neola inverter 11
- Service manual 11 11
- Specification 11
- Neola inverter dm13 01 1 2 en 12
- Service manual 12
- Dm13 01 1 2en neola inverter 13
- Service manual 13 13
- Neola inverter dm13 01 1 2 en 14
- Service manual 14
- Dimension 15
- Outdoor units 17
- 04 2 17 2 19 2 11 1 81 1 72 1 67 18
- 33 2 48 2 50 2 41 2 07 1 96 1 91 18
- 35 2 50 2 52 2 43 2 08 1 98 1 92 18
- 40 2 56 2 58 2 48 2 13 2 02 1 97 18
- 55 2 72 2 74 2 64 2 27 2 15 2 09 18
- 61 0 66 0 72 0 79 0 80 0 81 0 84 18
- 62 0 67 0 73 0 80 0 81 0 82 0 85 18
- 64 0 69 0 75 0 82 0 83 0 85 0 88 18
- 73 0 78 0 85 0 93 0 95 0 96 1 00 18
- 86 1 99 2 00 1 93 1 65 1 57 1 53 18
- 92 2 04 2 06 1 99 1 70 1 62 1 57 18
- 93 3 13 3 15 3 04 2 61 2 47 2 41 18
- Capacity tables 18
- Neola inverter dm13 01 1 2 en 18
- Service manual 18
- ºc 25ºc 30ºc 35ºc 40ºc 45ºc 50ºc 18
- Dm13 01 1 2en neola inverter 21
- Indoor outdoor 21
- Refrigerant cycle diagram 21
- Service manual 21 21
- Indoor units 22
- Wiring diagram 22
- Outdoor units 23
- 153kgf cm 25
- 163kgf cm 25
- 255kgf cm 25
- 265kgf cm 25
- 357kgf cm 25
- 367kgf cm 25
- And 10 1 25
- And 16 1 25
- And 25 2 25
- And 6 0 5 25
- Connecting the cables 25
- Dm13 01 1 2en neola inverter 25
- Installation details 25
- Mm inch n cm n cm 25
- On the nameplate which located on the side panel of the unit please refer to the nameplate before 25
- Outside diameter torque additional 25
- Pipe length and the elevation 25
- Rated current of appliance nominal cross sectional area mm² 25
- Selecting the cable fuse and switch 25
- Service manual 25 25
- The cable size and the current of the fuse or switch are determined by the maximum current indicated 25
- The pipe length and refrigerant amount 25
- The power cord of connect should be selected according to the following specifications sheet 25
- Tightening torque 25
- Wrench torque sheet for installation 25
- Ф12 1 2 3500 25
- Ф6 5 1 4 1500 25
- Ф9 2 3 8 2500 25
- Installation for the first time 27
- Adding the refrigerant after running the system for many years 30
- Re installation while the indoor unit need to be repaired 31
- Re installation while the outdoor unit need to be repaired 33
- Caution 36
- Operation characteristics 36
- Abbreviation 37
- Display function 37
- Electronic function 37
- Main protection 38
- Operation modes and functions 39
- Compressor running rules 42
- Heating mode 42
- If users switch on ac by remote controller the compressor will run at the fmax frequency for 7 42
- Minutes according to outdoor ambient temp during the 7 minutes the frequency limitation is active 42
- Minutes later the compressor running frequency will be controlled as below 42
- Neola inverter dm13 01 1 2 en 42
- Service manual 42
- The compressor frequency will not be limited 42
- The maximum operation frequency of the compressor after starting submits to the following rule 42
- Defrosting action 46
- For 18k 24k models 46
- For 9k 12k models 46
- Neola inverter dm13 01 1 2 en 46
- Service manual 46
- Xx 60 s for 18k models 46
- Xx 90 s for 24k models 46
- Indoor unit error display 51
- Troubleshooting 51
- Diagnosis and solution 52
Похожие устройства
- Midea MS11D-18HRDN1 Технические данные
- Midea MS11D-18HRDN1 Инструкция по монтажу
- Midea MS11D-18HRDN1 Инструкция по эксплуатации
- Сибконтакт ИБПС-24-500 DIN OffLine Руководство по эксплуатации
- Midea MS11D-24HRDN1 Сервис мануал
- Midea MS11D-24HRDN1 Технические данные
- Midea MS11D-24HRDN1 Инструкция по монтажу
- Midea MS11D-24HRDN1 Инструкция по эксплуатации
- Midea MO11D-09HRDN1 Сервис мануал
- Midea MO11D-09HRDN1 Технические данные
- Midea MO11D-09HRDN1 Инструкция по монтажу
- Midea MO11D-09HRDN1 Инструкция по эксплуатации
- Сибконтакт ИБПС-12-600ML1 Руководство по эксплуатации
- Midea MO11D-12HRDN1 Сервис мануал
- Midea MO11D-12HRDN1 Технические данные
- Midea MO11D-12HRDN1 Инструкция по монтажу
- Midea MO11D-12HRDN1 Инструкция по эксплуатации
- Сибконтакт ИБПС-12-1500ML1 Руководство по эксплуатации
- Midea MO11D-18HRDN1 Сервис мануал
- Midea MO11D-18HRDN1 Технические данные