Panasonic CU-A12ATP5 [20/56] Deice control

Panasonic CS-A18ATP5 [20/56] Deice control
7.5. Deice control
1.
Manual operation
When the airflow direction adjustment button of the remote
control is pressed, the louver moves up/down in the
movable range shown in the diagram at right, and can be
stopped at the required position.
Only the up/down louvers are adjustable from the remote
control.
2.
Automatic airflow direction
a. For cooling and soft dry
The up/down louver swings within the movable range.
b. For heating
As shown in the diagram at left, the blow out angle
changes according to the blow out temperature.
* Angle of the left/right louver is manually adjusted.
When AUTO (automatic operation) is set with the operation
mode selector on the remote control, the indoor fan runs at
Low speed for 20sec., the air conditioner unit senses the room
temperature then automatically selects the operation mode and
temperature setting.
1. Relationship between room temperature at start and
operation mode:
* Operation lamp flashes while fan is running for the first
20sec., then lights.
* At start of operation, if the room temperature is 16°Cor
lower, heating operation (hot start) starts immediately.
* Once the operation mode is determined by automatic
operation, that operation mode does not change unless
the air conditioner is stopped once and restarted or by
changing to a different mode using the operation mode
select button.
2. The 3 temperature settings listed below can be selected for
* High : +2 degrees up
* Standard :+0
* Low : -2 degrees down
Deicing operation is controlled by sensing the indoor piping temperature and timer.
Deicing starts when 60 minutes after start of heating or deice ends and if the indoor piping temperature is 46° (°C) or lower.
Deicing ends by function of the pressure switch or after 9 minutes of deice operation.
7.6. Airflow direction control
7.7. Automatic operation
20
CS-A12ATP5 CU-A12ATP5 / CS-A18ATP5 CU-A18ATPT5 / CS-A24ATP5 CU-A24ATPT5

Содержание

Скачать