Panasonic CS-E12EKEB / CU-E12EKEB Сервис мануал онлайн

1 Safety Precautions 3
2 Specification
5
2.1. CS-E9EKEB CU-E9EKEB
5
2.2. CS-E12EKEB CU-E12EKEB
7
3 Features
9
3.1. Super Air Purifying System with SUPER alleru-buster
9
3.2. Ion Freshener
9
3.3. Super Quiet
9
3.4. Powerful Heating And Top-class Energy Effciency
9
4 Location of controls and components
10
4.1. Indoor Unit
10
4.2. Outdoor Unit
10
4.3. Remote Control
10
5 Dimension
11
5.1. Indoor Unit & Remote Control
11
5.2. Outdoor Unit
12
© 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-E9EKEB CU-E9EKEB
CS-E12EKEB CU-E12EKEB
6 Refrigeration Cycle Diagram 13
7 Block Diagram
14
8 Wiring Diagram
15
8.1. CS-C9EKEB CS-C12EKEB
15
8.2. CU-C9EKEB CU-C12EKEB
16
9 Printed Circuit Board
17
9.1. Indoor Unit
17
9.2. Outdoor Unit
19
10 Simplified Electronic Circuit Diagram
21
10.1. Indoor Unit
21
10.2. Outdoor Unit
22
11 Installation Instructions
23
11.1. Select The Best Location
23
11.2. Indoor Unit
24
11.3. Outdoor Unit
27
Air Conditioner
CONTENTS
Page Page
Order No: MAC0510072C2
Содержание
- Air conditioner 1
- Contents 1
- Cs e9ekeb cu e9ekeb cs e12ekeb cu e12ekeb 1
- Page page 1
- Carry out test running to confirm that no abnormality occurs after the servicing then explain to user the operation care and maintenance as stated in instructions please remind the customer to keep the operating instructions for future reference 3
- Electrical work must be installed or serviced by a licensed electrician be sure to use the correct rating of the power plug and main circuit for the model installed 3
- Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage and the seriousness is classified by the following indications 3
- Read the following safety precautions carefully before perform any servicing 3
- Safety precautions 3
- The caution items stated here must be followed because these important contents are related to safety the meaning of each indication used is as below 3
- The items to be followed are classified by the symbols 3
- Cs e9ekeb cu e9ekeb 5
- Specification 5
- Specifications are subjected to change without prior notice for further improvement 6
- Cs e12ekeb cu e12ekeb 7
- Specifications are subjected to change without prior notice for further improvement 8
- Features 9
- Ion freshener 9
- Powerful heating and top class energy effciency 9
- Super air purifying system with super alleru buster 9
- Super alleru buster filter 9
- Super quiet 9
- Supersonic air purifying system 9
- Location of controls and components 10
- Dimension 11
- Wiring diagram 15
- Printed circuit board 17
- Installation instructions 23
- Select the best location 23
- How to fix installation plate 24
- Indoor unit 24
- Indoor unit installation 24
- To drill a hole in the wall and install a sleeve of piping 24
- Connect the cable to the indoor unit 26
- How to take out front grille 26
- Installation of super alleru buster filter 26
- Connecting the piping 27
- Install the outdoor unit 27
- Outdoor unit 27
- Connect the cable to the outdoor unit 28
- Evacuation of the equipment 28
- Check the drainage 29
- Evaluation of the performance 29
- Outdoor unit drain water 29
- Pipe insulation 29
- Airflow direction 30
- Automatic vertical airflow direction can be set using remote control the vane swings up and down within the angles as stated above for heating mode operation the angle of the vane depends on the indoor heat exchanger temperature as figure 1 below when the air conditioner is stopped using remote control the vane will shift to close position 30
- Basic function 30
- Control of airflow direction can be automatic angles of direction is determined by operation mode heat exchanger temperature and intake air temperature and manual angles of direction can be adjusted using remote control 30
- Internal setting temperature 30
- Inverter control which equipped with a microcomputer in determining the most suitable operating mode as time passes automatically adjusts output power for maximum comfort always in order to achieve the suitable operating mode the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting the compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air temperature 30
- Manual vertical airflow direction can be set using remote control the angles of the vane are as stated above and the positions of the vane are as figure 2 below when the air conditioner is stopped using remote control the vane will shift to close position 30
- Once the operation starts remote control setting temperature will be taken as base value for temperature shifting processes these shifting processes are depending on the air conditioner settings and the operation environment the final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit 30
- Operation and control 30
- There are two types of airflow vertical airflow directed by horizontal vane and horizontal airflow directed by vertical vanes 30
- Vertical airflow 30
- A powerful button is pressed 31
- A purpose 31
- A quiet operation start condition 31
- Automatic horizontal airflow direction can be set using remote control the vane swings left and right within the angles as stated below for heating mode operation the angle of the vane depends on the indoor heat exchanger temperature as figure 1 below 31
- B control condition 31
- B quiet operation stop condition 31
- B stop by off on switch 31
- C timer off activates 31
- D quiet button is pressed again 31
- Horizontal airflow 31
- Manual horizontal airflow direction can be set using remote control the angles of the vane are as stated below and the positions of the vane are as figure 2 above 31
- Quiet led illuminates 31
- Quiet operation cooling mode cooling area of dry mode 31
- To provide quiet cooling operation compare to normal operation 31
- When one of the following conditions is satisfied quiet operation stops 31
- When quiet button at remote control is pressed 31
- Quiet operation heating 32
- Off timer control 33
- On timer control 33
- Powerful mode operation 33
- Auto restart control 34
- Ionizer operation 34
- 30 seconds forced operation 35
- Compressor overheating prevention control 35
- Compressor protection control refrigeration cycle abnormality 35
- Ipm power transistor protection control dc peak detection 35
- Outdoor high pressure prevention control cooling and dry operations 35
- Protection control 35
- Time delay safety control 35
- Total running current control 35
- 0 outdoor air temperature control 36
- 1 indoor intake air temperature control heating operation 36
- Anti freezing control cooling and dry operations 36
- Four way valve operation detection control switching abnormality between cooling and heating 36
- A beep beep sound will occur at the fifth sec then release the auto switch 37
- A release the auto switch after test run operation is activated 37
- Auto operation mode 37
- Auto switch operation 37
- B then within 20 sec after a press auto switch for more than 5 sec 37
- C within 20 sec after b press auto switch again everytime auto switch is pressed within 20 sec interval remote controller receiving sound status will be reversed between on and off 37
- If ionizer led is blinking there is an abnormality of ionizer occurs 37
- If power led is blinking the possible operations of the unit are hot start during deice operation operation mode judgment or on timer sampling 37
- If timer led is blinking there is an abnormality operation occurs 37
- Indicator panel 37
- Long beep sound indicates that remote controller receiving sound is off 37
- Remote controller receiving sound on off 37
- Servicing mode 37
- Short beep sound indicates that remote controller receiving sound is on 37
- Test run operation for pump down servicing purpose 37
- The auto operation will be activated immediately once the auto switch is pressed 37
- The below operations will be performed by pressing the auto switch 37
- The on off of remote controller receiving sound can be change over by pressing the following step 37
- The test run operation will be activated if the auto switch is pressed continuously for more than 5 sec a beep sound will occur at the fifth sec in order to identify the starting of test run operation 37
- Refrigeration cycle system 38
- Troubleshooting guide 38
- Breakdown self diagnosis function 39
- Button once next error code will be displayed press v button once previous error code will be displayed 39
- By pressing the tmer 39
- Carry on the measurements of pressure electric current and temperature fifteen minutes after an operation is started 39
- If check button is press again or without any operation for 30 seconds the diagnosis mode will turn off 39
- If error code displayed matches the error code saved in unit memory abnormality detected beep beep beep sounds will be heard for 4 seconds and power led will light on otherwise one beep sound is heard 39
- Once abnormality detected during operation the unit will immediately stop its operation timer led is blinking and maximum of three error codes abnormality will be saved in memory the abnormality of the operation can be identified through the below breakdown diagnosis method 39
- Press check button at remote controller continuously for more than five seconds to turn on the diagnosis mode h11 will be displayed at remote controller 39
- Relationship between the condition of the air conditioner and pressure and electric current 39
- Although operation forced to stop when abnormality detected emergency operation is possible for certain errors refer to error codes table by using remote controller or auto switch at indoor unit however the remote controller signal receiving sound is changed from one beep to four beep sounds 40
- Error codes table 40
- The memory data of error code is erased when the power supply is cut off or press the auto switch until beep sound heard following by pressing the reset button at remote controller 40
- Disassembly and assembly instructions 41
- Indoor electronic controller and control board 41
- Cs e9ekeb cu e9ekeb 47
- Technical data 47
- Cs e12ekeb cu e12ekeb 53
- Condition 58
- Cs e12ekeb cu e12ekeb 58
- Cs e9ekeb cu e9ekeb 58
- Indoor temperature 27 c 19 c 58
- Ip input power kw 58
- Outdoor temperature 35 c 24 c 58
- Sensible capacity chart 58
- Shc sensible heat capacity kw 58
- Tc total cooling capacity kw 58
- Cs e9ekeb cs e12ekeb 59
- Exploded view and replacement parts list 59
- All parts are supplied from phaam malaysia vendor code 061 60
- Cs e9ekeb cs e12ekeb 60
- O marked parts are recommended to be kept in stock 60
- Cu e9ekeb cu e12ekeb 61
- All parts are supplied from phaam malaysia vendor code 061 62
- Cu e9ekeb cu e12ekeb 62
- O marked parts are recommended to be kept in stock 62
- Phaam printed in malaysia 62
Похожие устройства
- Аксион М642.03 Руководство по эксплуатации
- Аксион М61.02 Руководство по эксплуатации
- Аксион М61.03 Руководство по эксплуатации
- Аксион М642.04 Руководство по эксплуатации
- Аксион М642.01 Руководство по эксплуатации
- Аксион М42.02 Руководство по эксплуатации
- Аксион М61.04 Руководство по эксплуатации
- Аксион М61.01 Руководство по эксплуатации
- Аксион М42.03 Руководство по эксплуатации
- Аксион М641.02 Руководство по эксплуатации
- Аксион М42.04 Руководство по эксплуатации
- Аксион М641.03 Руководство по эксплуатации
- Аксион М42.01 Руководство по эксплуатации
- Аксион М641.04 Руководство по эксплуатации
- Аксион М641.01 Руководство по эксплуатации
- Аксион М43.02 Руководство по эксплуатации
- Аксион M41.00 Руководство по эксплуатации
- Аксион М41.03 Руководство по эксплуатации
- Аксион М43.03 Руководство по эксплуатации
- Аксион М43.04 Руководство по эксплуатации