Citizen CT-S2000 [345/565] Ct s4000

Citizen CT-E601 [345/565] Ct s4000
Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
CT-S751
CT-S4500
- 344 -
CT-S4000
• a=116: When kind of paper is specified
Setting Status
Stored
Value
Paper
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
Single-color paper
49(1)
-
-
-
-
2
2-color paper
50(2)
53(5)
55(7)
-
-
• a=201: When ACK output position is specified
Setting Status
Stored
Value
ACK Output
Position
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
ACK-in-Busy
49(1)
-
-
-
-
2
ACK-while-Busy
50(2)
-
-
-
-
3
ACK-after-Busy
51(3)
-
-
-
-
• a=202: Input buffer full Busy output/cancel timing
Setting Status
Stored
Value
BUSY
Output/Cancel
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
49(1)
-
-
-
-
2
50(2)
-
-
-
-
3
51(3)
-
-
-
-
4
52(4)
-
-
-
-
a=212: When DMA (Direct Memory Access) control of serial communication is specified
Setting Status
Stored
Value
DMA control
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
Invalid
49(1)
-
-
-
-
2
Valid
50(2)
-
-
-
-
a=213: When the flow control of virtual COM is specified.
Setting Status
Sending Data
Stored
Value
Flow control
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
PC setting
49(1)
-
-
-
-
2
DTR/DSR
50(2)
-
-
-
-
3
XON/XOF
51(3)
-
-
-
-
a=214: When Kanji is specified
Setting Status
Sending Data
Stored
Value
Kanji
1st Byte
2nd Byte
3rd Byte
4th Byte
5th Byte
1
OFF
49(1)
-
-
-
-
2
ON
50(2)
-
-
-
-

Содержание