Citizen CT-S851II [213/565] Gs c 2 n1 n2

Citizen CT-S601II [213/565] Gs c 2 n1 n2
Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
CT-S751
CT-S4500
- 212 -
GS C 2 n1 n2
[Function] Setting the numbering counter
[Code] <1D>H<43>H<32>H<n1><n2>
[Range] 0n1255
0n2255
[Outline] [The specification which is common to the model]
This command sets the numbering (serial number counter) value.
n1+n2×256 (n1=remainder, n2=quotient) becomes a counter value.
[Caution] If the counter value is beyond the range specified with the GS C1 or GS C; command, the counter value will
be the first value in counter data range.
[Default] Not defined.
[See Also] GS C 0, GS C 1, GS C , GS c
[Sample Program]
[Print Results]
See the Sample Program and Print Results for the GS C1 command.