MSW6-7 USB Power@PW-OFF (CT-S751 unique)
[Outline] Select whether to provide power from the USB power supply port when the printer is powered off.
OFF(0)
ON(1)
USB
Power@PW-OFF
Invalid
Valid
Operation when ON (1): Provide power from the USB power supply port when the printer is powered off.
Operation when OFF (0): Do not provide power from the USB power supply port when the printer is powered
off.
MSW6-8 Power On Trigger (CT-D150/CT-E351/CT-D151/ CT-E651 unique)
[Outline] Select what trigger makes the printer turn on.
OFF(0)
ON(1)
Power On Trigger
Power Switch ON
AC Power Input
ON (1) OPERATION: Printer turns on by the AC power input.
OFF (0) OPERATION: Printer turns on by the power switch.