Citizen PMU2300II [275/454] Ct s4000

Citizen PMU2300II [275/454] Ct s4000
- 274 -
CT-S4000
a=116: When kind of paper is specified
Setting Status Sending Data
Stored
Value
Paper
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1
Single-color
paper
49(“1”) - - - -
2 2-color paper 50(“2”) 53(“5”) 55(“7”) - -
a=201: When ACK output position is specified
Setting Status Sending Data
Stored
Value
ACK Output
Position
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 ACK-in-Busy 49(“1”) - - - -
2 ACK-while-Busy 50(“2”) - - - -
3 ACK-after-Busy 51(“3”) - - - -
a=202: Input buffer full Busy output/cancel timing
Setting Status Sending Data
Stored
Value
BUSY
Output/Cancel
1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 49(“1”) - - - -
2 50(“2”) - - - -
3 51(“3”) - - - -
4 52(“4”) - - - -
a=212: When DMA (Direct Memory Access) control of serial communication
is specified
Setting Status Sending Data
Stored
Value
DMA control 1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 Valid 49(“1”) - - - -
2 Invalid 50(“2”) - - - -
a=213: When the flow control of virtual COM is specified.
Setting Status Sending Data
Stored
Value
Flow control 1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 PC setting 49(“1”) - - - -
2 DTR/DSR 50(“2”) - - - -
3 XON/XOF 51(“3”) - - - -
a=214: When Kanji is specified
Setting Status Sending Data
Stored
Value
Kanji 1st Byte
2nd
Byte
3rd Byte 4th Byte 5th Byte
1 OFF 49(“1”) - - - -
2 ON 50(“2”) - - - -