Removal / installation of protective casing (see
g.1)
[HLP20-600 K]
Turn protective casing 2 and remove it as shown on
g. 1 (this may be necessary for performing works in
conned spaces).
While installing protective casing 2 match the raised
elements inside the casing with the slots in housing 3,
put the casing on and turn as shown on g. 1.
Using special nozzles (see g. 2)
Put a special nozzle on nozzle 1 and turn, it if neces-
sary, to adjust it to a position more suitable for work
(see g. 2). Notice that a special nozzle must be put on
evenly so that it will not fall off during operation.
Initial operating
of the power tool
Always use the correct supply voltage: the power
supply voltage must match the information quoted on
the power tool identication plate.
Switching the power
tool on / off
[HLP16-500]
Switching on:
Move on / off switch 5 in position "1" or "2".
Switching off:
Move on / off switch 5 in position "0".
[HLP20-600 K]
Switching on:
Move on / off switch 5 in position "1", "2" or "3".
Switching off:
Move on / off switch 5 in position "0".
Design features
of the power tool
Air ow adjustment
[HLP20-600 K]
The air ow may be adjusted stepwise using on / off
switch 5. Move it in position "1", "2" or "3" to set the
desired air ow (values are specied in the technical
data sheet).
Temperature adjustment
[HLP20-600 K]
The air ow temperature can be smoothly changed
with regulator 6 (only if on / off switch 5 is placed in po-
sitions "2" or "3"). Rotate regulator 6 to set the desired
temperature (also see the marking on regulator 6 - it
should be read through sight hole 7).
Cool air blowing
[HLP20-600 K]
If on / off switch 5 is placed in position "1", the heating
element is not activated, and only the fan is running.
This mode is intended for cooling the power tool after
operation, and it also can be used for cooling, blowing
and drying.
Possibility of steady-state use (see g. 5.1)
The power tool design allows steady-state operation.
Switch the power tool on, set the desired temperature
(only for HLP20-600 K model) and then put it in a
vertical position with the nozzle up (see g. 5.1). Note:
before vertical installation of HLP16-500 model,
please put bracket 13 parallel to body 3.
Protection against overheating
[HLP16-500]
The power tool is equipped with a complex protection
against overheating which prevents damage to the
power tool when normal operating temperature is
exceeded.
Recommendations
on the power tool operation
Range of application of the power tool
Using the power tool allows different types of work to
be performed. Some of them are listed below.
Contracting heat shrink pipes, soldering connec-
tors and clamps of sealing and electrical compo-
nents.
Changing the shape of acryl, PVC, polystyrene
products, pipes, plates, proles and wet timber.
Repairing surfboards, skis and other sports equip-
ment, repairing bumpers and other plastic automobile
parts.
Waxing skis, furniture, and antiseptic timber treat-
ment.
Loosening rusted or tight metal screws, nuts, bolts,
shrink-tting, heat shrink treatment.
Welding thermoplastic polymers, PVC and linoleum
ooring materials, PVC coated fabrics, tarpaulin and
foil.
Soldering, tinplating and loosening of soldered
joints.
Removing lacquer and paint coatings.
Drying lacquer and paint coatings, adhesive and
spackling compounds.
Acceleration of adhesion processes, activation of
adhesives.
Thawing ladders, stairs, door locks, boot covers, car
doors, water pipes as well as defrosting fridges and
freezers.
Mold and fungus control, disinfection of animal
housing.
Lighting charcoal.
Using special nozzles
Flat nozzle 9 is designed for treating large-area
surfaces.