Electric motor care
It is necessary to be especially careful with the electric motor, to prevent the ingress of liquids and foreign objects
into the case. Keep the air vents clean, blow them regularly with compressed air or clean them with a brush.
In case of noticeable sparks in the ventilation holes of the motor housing, contact an authorized service center
for diagnostics and, possibly, replacement of carbon brushes.
In case of any damage to the power cord, immediately turn o the machine; carefully, without touching the damaged
points, unplug it from the mains.
ATTENTION!
Circular saws use power cord with mounting type Y: for security it must be replaced by
authorized repair shop personnel.
Possible faults
Fault Probable cause Elimination method
The tool does not turn on.
Broken power cord or mounting
wire, power cord malfunction.
Call the service center.
Faulty switch. Call the service center.
Brush wear. Call the service center.
Formation of a circular
light on the collector.
Fault in the armature winding. Call the service center.
Wearout /”hang ” of brushes. Call the service center.
When working smoke
or smell
of burning insulation
is generated from the vent.
Interturn closure of armature
or stator windings.
Call the service center.
Malfunction of the electrical part
of the instrument.
Call the service center.
Increased machine
vibration.
Damage or deformation of the sole. Call the service center to replace the sole.
Faulty or improperly installed saw
blade.
Replace or reinstall a saw blade.
RECYCLING
A tool, developed a designated service life, must be recycled according the rules established by environmental
and other laws of the country, where the tool is operated.
STORAGE
During the assigned service life, store the machine in a dry heated room. Recommended storage temperature
from 0 °C to +40 °C. Store the tool in original packaging.
TRANSPORTATION
During the transportation it is unacceptable direct exposure of precipitation, direct sunlight, heat and shock.
Transportation should be carried out only in original packaging at ambient temperature from -20 °С to +40 °С.
Transport the machine in original packaging. Roll up and secure the cord before packing.