18.2 Troubleshooting Charger
The shrub shears cut
out during operation.
3 LEDs emit red
light.
Shrub shears are too hot. Remove the battery.
Allow the shrub shears to cool down.
There is an electrical fault. Remove battery and reinsert it.
Switch on the shrub shears.
The shrub shears
runtime is too short.
The battery is not fully
charged.
Fully charge the battery.
The battery service life has
been exceeded.
Replace battery.
Fault LEDs on shrub
shears
Cause Remedy
Condition LED on Charger Cause Remedy
Battery not being
charged.
One LED glows
red.
Battery too hot or too cold. Leave battery in the charger.
Charge process starts automatically as soon as
permissible temperature range is reached.
LED flashes red. No electrical contact
between charger and
battery.
Remove the battery.
Clean contacts on charger.
Fit the battery.
There is a malfunction in
the charger.
Do not use the charger and contact your STIHL
dealer for assistance.
There is a malfunction in
the battery.
Do not use the battery and contact your STIHL
dealer for assistance.
The charger (3) does
not run a self test.
The LED (4) glows
green for about
1 second and then
red for about
1 second.
Electrical contact to
charger was briefly
interrupted.
Disconnect the plug from the wall outlet.
Wait 1 minute.
Insert the plug in a wall outlet.