A. Introduction
This product is a battery-powered, true-rms, auto-ranging digital multimeter with
a 4000 counts, LCD display and backlight/flashlight.
B. Safety Information
To avoid possible electrical shock, fire, or personal injury, please read all safety
information before you use the product.
(1) Do NOT exceed the “maximum value” indicated in the Specification.
(2) Examine the connection of the test leads and the insulation of the product
before measuring voltage higher than 36V DC or 25V AC.
(3) Disconnect the test leads from the circuit before changing the mode。
(4) Misuse of mode or range can lead to hazards, be cautious. “OL” will be shown
on the display when the input is out of range.
(5) Safety symbols:
C. Specifications
- 1 - - 3 -
- 4 -
- 2 -
Electrical Specifications
Function Range
Resolution
Accuracy
MAX.Value
Other
DC Voltage
(V)
4.000V
0.001V
±(0.5%+3)
600V
40.00V
0.01V
400.0V
0.1V
600V
1V
DC Voltage
(mV)
40.00mV
0.01mV
400mV
400.0mV
0.1mV
AC Voltage
(V)
4.000V
0.001V
±(1.0%+3)
600V
Frequency Response:
40Hz
-1kHz
40.00V
0.01V
400.0V
0.1V
600V
1V
AC Voltage
(mV)
40.00mV
0.01mV
400mV
400.0mV
0.1mV
DC Current
(A)
4.000A
0.001A
±(1.2%+3)
10A
MAX.Current
:10A(no
more than 15 seconds
)
No Voltage input at this
mode
Frequency Response(AC):
40Hz
-1kHz
10.00A
0.01A
DC Current
(mA)
40.00mA
0.01mA
400mA
400.0mA
0.1mA
AC Current
(A)
4.000A
0.001A
±(1.5%+3)
10A
10.00A
0.01A
AC Current
(mA)
40.00mA
0.01mA
400mA
400.0mA
0.1mA
Function Range
Resolution
Accuracy
MAX.Value
Other
Resistance
400.0
Ω
0.1
Ω
±(0.5%+3)
40MΩ
No Voltage input at
this mode
4.000k
Ω
0.001k
Ω
40.00k
Ω
0.01k
Ω
400.0k
Ω
0.1k
Ω
4.000M
Ω
0.001M
Ω
40.00M
Ω
0.01M
Ω
±(1.5%+3)
Frequency
4.000Hz
0.001Hz
±(1%+2) 10.00MHz
40.00Hz
0.01Hz
400.0Hz
0.1Hz
4.000kHz
0.001kHz
40.00kHz
0.01kHz
400.0kHz
0.1kHz
10.00MHz
0.01MHz
Capacitance
4.000nF
0.001nF
±(5.0%+20)
4mF
40.00nF
0.01nF
±(3.5%+4)
400.0nF
0.1nF
4.000uF
0.001uF
40.OOnF
0.01uF
400.0uF
0.1uF
4mF
0.001mF
±(5.0%+5)
Temperature
-30℃-1000℃(-22℉-1832℉)
No Voltage input at
this mode
NCV √
Diode
√(DC forward current is 5mA,voltage is 3V)
Continuity √(no more than 50Ω)
General Specifications
Display
(LCD)
4000 counts
Ranging
Auto
Material
ABS/PVC
Update Rate
3 times/second
Ture RMS
√
Data Hold
√
Backlight/Flashlight
√
Low Battery Alert
√
Auto Power Off
√
Mechanical Specifications
Dimension
120*60*33mm
Weight
137.5g
Battery Type
1.5V AAA Battery * 2
Warranty
One year
Environmental Specifications
Operating
Temperature 0~40℃
Humidity
<75%
Storage
Temperature -20~60℃
Humidity
<80%
D. Instruction
(1) Front Panel(see the picture on the right)
1. LCD display
2. buttons
2a. HOLD: To hold the current reading, press
this button and you will see “HOLD” on the
display; press again to cancel. To turn on
the backlight and flashlight, press this
button for more than 2 seconds; long-press
again to turn off.
2b. SELECT: To toggle between AC/DC,
Resistance/Capacitance/Diode/Continuity
when you press this button.
3. Rotary Switch: To change mode or range。
(from OFF, clockwise)
3a. OFF
3b. AC/DC Voltage (V)/Frequency (Voltage-V)
3c. AC/DC Voltage (mV)/Frequency(Voltage-mV)
3d. Continuity/Diode/Resistance/Capacitance
3e. Temperature
3f. NCV
3g. AC/DC Current (A) (Cureent-A)
3h. AC/DC Current (mA) (Current-mA)
4. : Input terminal for voltage, resistance, capacitance, frequency, temperature,
current (mA), continuity, diode, and duty cycle measurements.
5. COM: Common terminal for all measurements.
6. 10A: Input terminal for current (V) measurements.
Do not input voltage exceeds 36V DC or 25V AC when you are at the
setting of measuring current.
- 1 -
- 2 -
1
2a
2b
3
4
5
6
(2) Measure AC/DC Voltage
1. Connect the black test lead to the COM Terminal and connect the red test lead to
the Terminal;
2. Turn the rotary switch to the Voltage-V Mode or the Voltage-mV Mode;
3. Press SELECT to toggle between AC/DC;
4. Touch the probes to the correct test points of the circuit to measure the voltage;
5. Read the measured voltage on the display.
*Caution:
a. Do not measure voltage that exceeds the MAX Value as indicated in the
Specifications;
b. Do not touch high voltage circuit during measurements.
Содержание
- 1 3 4 2 1
- Ac voltage 1
- Hz 1khz 1
- Nf 0 nf 1
- No voltage input at 1
- Oonf 0 1uf 1
- Read the measured voltage on the display 1
- Resistance capacitance diode continuity 1
- User manual 1
- 5 7 8 6 2
- And limitation of liability 2
- Caution 2
- Changing batteries or fuses 2
- Limited warranty 2
- Performancetest and service instructions 2
- Read the measured frequency dutycycle value on the display 2
- The product automatically powers off after 15 minutes of inactivity 2
Похожие устройства
- Zotek ZT-S2 Инструкция по эксплуатации
- Yli Electronic YK-1068B Спецификация
- Zotek ZT-S3 Инструкция по эксплуатации
- Zotek ZT-S4 Инструкция по эксплуатации
- Zotek ZT-301 Инструкция по эксплуатации
- Yli Electronic YD-605 Спецификация
- Zotek ZT-302 Инструкция по эксплуатации
- Yli Electronic YM-280NT(LED) Спецификация
- Zotek VC15B+ Инструкция по эксплуатации
- Zotek VC17B+ Инструкция по эксплуатации
- Zotek ZT-KP2 Инструкция по эксплуатации
- Zotek ZT-5566 Инструкция по эксплуатации
- Zotek ZT-81 Инструкция по эксплуатации
- Zotek ZT-82 Инструкция по эксплуатации
- Zotek ZT-A2 Инструкция по эксплуатации
- Zotek ZT-5B Инструкция по эксплуатации
- Zotek ZT-M0 Инструкция по эксплуатации
- Zotek ZT922 Инструкция по эксплуатации
- Zotek ZT922SE Инструкция по эксплуатации
- Zotek VC921 Инструкция по эксплуатации