Zotek ZT-5BQ Инструкция по эксплуатации онлайн

Zotek ZT-5BQ Инструкция по эксплуатации онлайн
Hazardous Voltage
Earth
Double Insulated
Low
Battery
Risk of Danger. Check
the User Manual.
N/
L Wire Judgement
User Manual
- 1 - - 3 -
- 4 -
- 2 -
Electrical Specifications
Function Range
Resolution
Accuracy
MAX.Val
ue
Frequency Response
DC Voltage
(V)
6
.000V
0.001V
±(0.5%+3)
600V
6
0.00V
0.01V
6
00.0V
0.1V
AC Voltage
(V)
6
.000V
0.001V
±(1.0%+3)
600V
40Hz-1kHz
6
0.00V
0.01V
6
00.0V
0.1V
AC Current
(A)
6
.000A
0.001A
±(5%+30)
600A 40Hz-1kHz
6
0.00A
0.01A
±
(2.5
%+30)
6
00.0A
0.1A
Function Range
Accuracy MAX.Value
Frequency Response
Resistance
6
.000kΩ
±(1.5%+3)
60MΩ 40Hz -1kHz
6
0.00kΩ
±(0.5%+3)
6
00.0kΩ
6.000M
Ω
Ω
60.
00MΩ
Frequency
9.999
Hz
±(0.1%+2)
9.999MHz 40Hz-1kHz
99.99
Hz
999.9
Hz
9.999
kHz
99.99
kHz
999.9
kHz
9.999
MHz
Capacitance
9.999nF
±(5.0%+20)
4.000mF 40Hz-1kHz
99.99nF
±(2.0%+5)
999.9nF
9.999μF
99.99μF
999.9μF
4.000mF
±(5.0%+5)
Diode
Continuity
Inrush Current
Peak Hold
Flashlight
Temperature
(
-30~1000)
±(2.5%+5
(
-22~1832)
General Specifications
Display
LCD
6000 counts
Ranging
Auto
Material
ABS
Update Rate
3 times/second
Ture RMS
Data Hold
Low Battery Alert
Auto Power Off
Mechanical Specifications
Dimension
172*64*32mm
Weight
172g
Battery Type
1.5V AA Battery * 2
Warranty
One year
Environmental Specifications
Operating
Temperature 0~40
Humidity
75%
Storage
Temperature -20~60
Humidity
80%
D. Instruction
(1) Front Panelsee the picture on the right
1. Jaw
2. Flashlight
3. Jaw release
4. Hold / Inrush Current / Peak Hold
HOLD: To press this button once and you will see
“HOLD” on the display;
Inrush current: To press this button twice
and you will see “INRUSH” on the display;
Peak hold: To press this button twice after
connecting test leads to the Terminals and you
will see Peak HOLD” on the display;
5. Power / Select
Power: Press this button for more than 2 seconds
to turn it on / off.
Select: Press this button for switching functions
after connecting test leads to the Terminals.
6. Frequency / NCV: Press this button over 2 seconds
into NCV mode and exit from release.
7. LCD display
8. COM: Common terminal for all measurements.
9. : Input terminal for voltage, resistance, capacitance, temperature, frequency,
continuity, diode measurements and judging N/L wires.
10. Wire to be measured
11. Marked position
- 1 -
- 2 -
(2) Measure AC/DC Voltage
1. The minimum voltage of this product is 0.8V. When the measured voltage is higher
than 0.8V, the product will display the reading;
2. Connect the black test lead to the COM Terminal and connect the red test lead to
the Terminal;
3. The DC or AC voltage will be matched automatically;
4. Touch the probes to the correct test points of the circuit to measure the voltage;
5. Read the measured voltage on the display.
*Caution:
a. Do not measure voltage that exceeds the MAX Value as indicated in the
Specifications;
b. Do not touch high voltage circuit during measurements.
1
11
10
2
3
4
5
6
7
9
8
A. Introduction
This product is a battery-powered, true-rms, auto ranging digital clamp
multimeter with a 6000 counts LCD display and a backlight.
B. Safety Information
To avoid possible electrical shock, fire, or personal injury, please read all safety
information before you use the product.
(1) Do NOT exceed the maximum value indicated in the Specification.
(2) Examine the connection of the test leads and the insulation of the product
before measuring voltage higher than 36V DC or 25V AC.
(3) Disconnect the test leads from the circuit before changing the mode
(4) Misuse of mode or range can lead to hazards, be cautious. “OL” will be shown
on the display when the input is out of range.
(5) Safety symbols:
C. Specifications
Скачать