Graco Reactor E-20 FH9030 — инструкция по ремонту насосов: пошаговое руководство [27/76]

Превью страниц Страница 27 / 76
Graco Reactor E-20 FP9030 Техническая документация онлайн [27/76] 679791
Repair
312066ZAF 27
NOTE: Steps 7-9 apply to pump A. To disconnect pump
B, go to steps 10 and 11.
7. Disconnect fittings at fluid inlet (C) and outlet (D, out
of view). Also disconnect steel outlet tube from
heater inlet.
8. Disconnect tubes (T). Remove tube fittings (U) from
wet-cup.
9. Loosen locknut (G) by hitting firmly with a
non-sparking hammer. Unscrew pump far enough to
separate and push up finger guard (P), to expose
rod retaining pin. Push retaining wire clip up. Push
pin out. Continue unscrewing pump.
NOTE: Steps 10 and 11 apply to pump B.
10. Disconnect fluid inlet (C) and outlet (D). Also
disconnect steel outlet tube from heater inlet.
11. Push retaining wire clip (E) up. Push pin (F) out.
Loosen locknut (G) by hitting firmly with a
non-sparking hammer. Unscrew pump.
TI3765a-2
C
U
G
D
T
P
TI3765a-1
C
F
G
D
E

Содержание

160