Temperature Control Diagnostic Codes
312066ZAF 11
3. Check connections between the temperature
control board and overtemperature switches A and
B (308), and between temperature control board
and thermocouples A and B (310) or FTS (21)
[depending on which zone is displaying E01]. See
Table 5, page 39. Ensure that all wires are securely
connected to connector B.
4. Remove connector B from temperature control
module, and check continuity of overtemperature
switches A and B, thermocouples A and B, or FTS
by measuring resistance across the pins on the plug
end; see T
ABLE 1.
NOTE: Before doing the following checks, note which
zone (A, B, FTS, or all) has high fluid temperature.
5. Verify fluid temperature, using an external
temperature sensing device.
• If temperature is too high (sensor reading is
229°F [109°C] or above):
6. Check if thermocouples A and B are damaged, or
not contacting the heater element, page 43.
7. To test that temperature control module turns off
when equipment reaches temperature setpoint:
a. Set temperature setpoints far below displayed
temperature.
b. Turn zone on. If temperature rises steadily,
power board is failing.
c. Verify by swapping with another power module.
See Replacing Temperature Control
Assembly Modules, page 40.
d. If the swapped module does not fix the problem,
the power module is not the cause.
8. Verify continuity of heater elements with an
ohmmeter, see page 41.
E02: High zone current
1. Turn main power OFF .
2. Perform the Pressure Relief Procedure, page 25.
NOTE: Disconnect whip hose.
3. Disconnect hose connector (D) at Reactor.
4. Using an ohmmeter, check between the two
terminals of the connector (D). There should be no
continuity.
5. Exchange zone module with another one. Turn
zone on and check for error. If error disappears,
replace faulty module.
For hose zone: If error still occurs, perform
Transformer Primary Check and Transformer
Secondary Check starting on page 47.
NOTE: When there is a a high current error, the LED on
that zone’s module will turn red while the error is
displayed.
Table 1: Sensor Connector Continuity Checks
Pins Description Reading
1 & 2 OT switch A nearly 0 ohms
3 & 4 OT switch B nearly 0 ohms
5 & 6 Thermocouple A 4-6 ohms
8 & 9 Thermocouple B 4-6 ohms
11 & 12 FTS approximately 35 ohms
per 50 ft (15.2 m) of
hose, plus
approximately 10 ohms
for FTS
10 & 12 FTS open
Содержание
160- Repair parts
- Contents
- E 30 series
- E 20 series
- E xp1 series
- Models
- Maximum flow rate given for 60 hz operation for 50 hz operation maximum flow rate is 5 6 of 60 hz maximum flow
- Full load amps with all devices operating at maximum capabilities fuse requirements at various flow rates and mix chamber sizes may be less
- E xp2 series
- Total system watts based on maximum hose length for each unit e 20 and e xp1 series 210 ft 64 m maximum heated hose length including whip hose e 30 and e xp2 series 310 ft 94 m maximum heated hose length including whip hose
- Supplied manuals
- Related manuals
- Approvals
- Warnings
- Warning
- Warning
- Warning
- Isocyanate conditions
- Important two component material information
- Keep components a and b separate
- Foam resins with 245 fa blowing agents
- Check with your material manufacturer for chemical compatibility
- Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime
- Changing materials
- Always clean the fluid inlet strainers after flushing
- When changing materials flush the equipment multiple times to ensure it is thoroughly clean
- When changing between epoxies and urethanes or polyureas disassemble and clean all fluid components and change hoses epoxies often have amines on the b hardener side polyureas often have amines on the b resin side
- Notice
- Moisture sensitivity of isocyanates
- Material self ignition
- Temperature control diagnostic codes
- E01 high fluid temperature
- Checks
- Causes of e01 errors
- E02 high zone current
- E06 communication cable unplugged
- E05 circuit board overheated
- E04 fluid temperature sensor fts or thermocouple disconnected
- E03 no zone current
- Motor control diagnostic codes
- Alarms
- Warnings
- Fast e24 errors
- E24 pressure imbalance
- E23 high fluid pressure
- E22 no component b transducer
- E21 no component a transducer
- Causes of fast e24 errors
- Slow e24 errors
- Checks for fast e24 errors
- Causes of slow e24 errors
- E29 brush wear
- E28 high current in motor
- E27 high motor temperature
- E26 low line voltage
- E25 high line voltage
- E31 motor control failure e 30 and e xp2 only
- E99 loss of communication
- E32 motor control overtemperature
- E30 momentary loss of communication
- Communication diagnostic codes
- Troubleshooting
- Reactor electronics
- Primary heaters a and b
- Problems
- Hose heat system
- Repair
- Pressure relief procedure
- Before beginning repair
- Pump removal
- Flushing
- Pump installation
- Install pump b
- Install pump a
- Removal
- Installation
- Drive housing
- Motor brushes
- Brush removal
- Brush installation
- Circuit breaker module
- Capacitor test
- Removal
- Installation
- Electric motor
- Motor control board
- On down
- Transducers
- Electric fan
- Temperature control module
- Test scr circuit
- Replacing temperature control assembly modules
- Line voltage
- Primary heaters
- Heater element
- Thermocouple
- Overtemperature switch
- Heated hose
- Check hose power connectors
- Check fts cables
- Test removal
- Installation
- Fluid temperature sensor fts
- Transformer primary check
- Replace transformer
- Transformer secondary check
- Temperature and pressure displays
- Red stop button
- Display module
- Inlet fluid strainer screen
- Pump lubrication system
- Reactor assembly model e xp1 shown
- Right side of cabinet
- Left side of cabinet
- Detail fluid manifold area detail fluid manifold area
- Detail cabinet area
- See pages 56 through 58 for parts that vary by model
- Parts used on all models
- Use the following tables on this and the next two pages to find parts that vary by model find the reference number and of part in left column and reactor model in top row intersection is correct part number
- See page 55 for parts common to all models
- Parts that vary by model
- Replacement danger and warning labels tags and cards are available at no cost
- Parts that vary by model continued
- Not required for slotted u channel style heater support rails
- Not for sale
- Sub assemblies
- Proportioner module
- Proportioner module parts list
- Fluid heaters
- 6 kw fluid heaters 247507 10 kw fluid heaters
- Part 247509
- Kw single zone fluid heater
- Reactor frame
- Display
- Temperature control
- Motor control
- Fluid manifold
- Circuit breaker modules
- B 400v 3 phase circuit breaker modules e 20 e xp1
- A 230v 3 phase circuit breaker modules e 20 exp 1
- D 230v 3 phase circuit breaker modules e 30 exp 2
- C 230v 1 phase circuit breaker modules e 20 exp 1
- F 230v 1 phase circuit breaker modules e 30 exp 2
- E 400v 3 phase circuit breaker modules e 30 e xp2
- Not for sale
- Circuit breaker modules parts list
- Conversion kit
- Dimensions
- Technical specifications
- All trademarks or registered trademarks are the property of their respective owners
- For the latest information about graco products visit
- For patent information see
- Copyright 2019 graco inc all graco manufacturing locations are registered to iso 9001 www graco com revision zaf november 2019
- Www graco com patents
- Www graco com
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6921 or toll free 1 800 328 0211 fax 612 378 3505
- Graco standard warranty
- Graco information
- Graco inc and subsidiaries p o box 1441 minneapolis mn 55440 1441 usa
- Graco headquarters minneapolis international offices belgium china japan korea
Похожие устройства
-
Graco REACTOR 2 H-50 PHH156Техническая документация -
Graco REACTOR 2 H-50 PHH156Сертификат -
Graco REACTOR 2 H-50 PHH156Брошюра -
Graco REACTOR 2 H-50 PHH156Инструкция по эксплуатации -
Graco REACTOR 2 H-50 PHH153Техническая документация -
Graco REACTOR 2 H-50 PHH153Сертификат -
Graco REACTOR 2 H-50 PHH153Брошюра -
Graco REACTOR 2 H-50 PHH153Инструкция по эксплуатации -
Graco REACTOR 2 H-50 PHH056Техническая документация -
Graco REACTOR 2 H-50 PHH056Сертификат -
Graco REACTOR 2 H-50 PHH056Брошюра -
Graco REACTOR 2 H-50 PHH056Инструкция по эксплуатации
Узнайте, как диагностировать коды управления температурой и проверять соединения между платами и датчиками. Подробные инструкции и советы по устранению неполадок.