Coolingfanon
backofmotornot
operatingproperly.
Ensurefanisalwaysrunningwhen
machineispoweredon.
Ensurefanisblowingairtowardthe
motor(inward).
Ensurefaniscleanandmoves
freely.Removeanyobstructionsin
frontoffangrill.
Ensurenohotair(fromotherheat
sources)isbeingdirectedtoward
thefan.
Ambient
temperatureistoo
high.
Ensuresystemambienttemperature
isbelow120°F(48°C).
T3NM
MCM
Motor
Temperature
Cutback
Machineis
operatingabove
pressure/󰘱ow
rating.
Mixchamberistoolargeforset
pressure.
Setpressureistoohighforgivenmix
chamber.
NOTE: NOTE:
NOTE:
Thiscutbackoccursto
preservemotorlife.Ifthemotorgets
toohotthisadvisoryautomatically
reducesthepressuresetpointto
allowthemotortocool.Toavoid
thisadvisory,runthesystemata
lowerdutycycleorwithasmallermix
chamber.
Highambient
temperature.
Ensureambienttemperatureisbelow
120°F(48°C)beforeusingthe
system.
T4CMMCM
High
Temperature
MCM
Enclosurefannot
operating.
Ensurefaninelectricalenclosureis
spinning.Ifitisnot,checkfanwiring
orreplacefan.
Highambient
temperature.
Ensureambienttemperatureisbelow
120°F(48°C)beforeusingthe
system.
Enclosurefannot
operating.
Ensurefaninelectricalenclosureis
spinning.Ifitisnot,checkfanwiring
orreplacefan.
T4CTTCM
High
Temperature
TCM
Modulefannot
operating.
IfaTCMfanerror(WMI0)has
occurred,faninsidethemoduleisnot
workingproperly.CheckTCMfan
fordebrisandclearwithforcedairif
necessary.