Graco Reactor 2 E-30 FH2110 Техническая документация онлайн [30/114] 679823

Graco Reactor 2 E-30 FH2110 Техническая документация онлайн [30/114] 679823
Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
BadRTDorbad
RTDplacement
againstheater.
SwapAandBheateroutputcables
andRTDcablesandseeifissue
follows.Ifso,replaceRTD.
T4DAHeaterAHigh
Temperature
A
Flowtoohigh
fortemperature
setpoint,causing
temperature
overshootswhen
gunisde-triggered.
Useasmallermixchamberthatis
ratedfortheunitinuse.
BadRTDorbad
RTDplacement
againstheater.
SwapAandBheateroutputcables
andRTDcablesandseeifissue
follows.Ifso,replaceRTD.
T4DBHeaterBHigh
Temperature
B
Flowtoohigh
fortemperature
setpoint,causing
temperature
overshootswhen
gunisde-triggered.
Useasmallermixchamberthatis
ratedfortheunitinuse.
30 333024T