Advanced dimensioning
For advanced dimensioning please use following equations
Oil carry over (c) can be determined by measuring oil volume at two sequential compressor
services. In order to determine oil carry over compare initial volume of new oil with
volume of oil drained out of compressor at oil replacement. It is recommended to keep a
record of compressor services. When oil carry over is not known we suggest to use c(oil
carryover)=0,005g/Nm³.