28
CAUTION
During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should not
drip from underneath it.
In this event, a Skilled Technician should test the appliance.
7.2 sp e c I a l ma I n t e n a n c e
WARNING
Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE ACTION
Every 100 hours Check the pump hydraulic circuit.
Check the pump xing.
Ad just the electrodes.
Clean the gas oil nozzle.
Check/replace the gas oil lter.
Check/replace the inner water inlet lter.
Every 200 hours Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.
Every 500 hours Replace the electrodes.
Replace the gas oil nozzle.
Clean the boiler.
Descale the coil.
CAUTION
• e data in the table are indications.
8 dI s m a n t l I n G an d dI s p o s a l
Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the current regulations
in the country where it is installed.
In particular, the symbol
on the identication plate (12) indicates the product must not be disposed of together
with normal household waste.
For further information, contact your local authority’s waste disposal service or your local retailer.
WARNING
Before disposing of the high pressure cleaner, make sure it is no longer possible to operate it, by cutting the power supply
cable for example. Make sure all its parts are inoffensive, as they could prove to dangerous to children playing.