Oleo-Mac PW 300 HС [25/120] Warning before undertaking any action follow the instructions in the switching off section if it is not possible to restore correct operation of the high pressure cleaner u...

Oleo-Mac PW 300 HС [25/120] Warning before undertaking any action follow the instructions in the switching off section if it is not possible to restore correct operation of the high pressure cleaner using the information in the table below contact a skilled technician
29
9 pr o b l e m s , ca u s e s an d so l u t I o n s
WARNING
Before undertaking any action, follow the instructions in the “Switching off” section. If it is not possible to restore correct
operation of the high pressure cleaner using the information in the table below, contact a Skilled Technician.
PROBLEMS CAUSES SOLUTIONS
By setting the switch (2) to
“1”, the water cleaner does
not start.
Remember also what
mentioned in the note of
section “Interrupting the use
(Total Stop)”
A safety device of the system to which
the water cleaner is connected (fuse,
dierential switch, etc.) has triggered.
e plug of the power supply cable
is not inserted correctly.
Reset the protection device.
In case of a new triggering, do not use the water
cleaner and apply to a Skilled Technician.
Disconnect the plug from the socket and
reconnect it correctly.
e water cleaner vibrates a
lot and is noisy.
e water suction lter/gasket (33)
and/or the inner water inlet lter is dirty.
e water supply is not enough.
Observe what mentioned in the section
“Routine maintenance” and “Special maintenance”.
Check that the tap is completely opened and that
the capacity of the hydraulic network conforms
with what mentioned in the section “Features and
technical specications”.
e water cleaner does
not reach the maximum
pressure.
e nozzle-holding head (18) is in low
pressure position (Fig. 1-a).
e water nozzle (20) is worn.
Rotate the nozzle-holding head as shown in Fig.
1-b.
Replace the nozzle according to what mentioned in
the section “Features and technical specications”.
Poor detergent suction. e nozzle-holding head (18) is in low
pressure position (Fig. 1-b).
e used detergent is too viscous.
Product missing in the tank.
Rotate the nozzle-holding head as shown in Fig.
1-a.
Use a detergent that is recommended by the
producer,by observing the thinning indicated on
the label.
Add product to the tank.
No water comes out from
the nozzle (20).
Water missing.
Water nozzle clogged.
Check that the tap of the water network is
completely opened.
Clean and/or replace the nozzle according to what
mentioned in the section “Features and technical
specications”.
e water cleaner stops
during the operation.
A safety device of the system to which
the water cleaner is connected (fuse,
dierential switch, etc.) has triggered.
e amperometric protection device
has cut in.
Reset the protection device.
In case of a new triggering, do not use the water
cleaner and apply to a Skilled Technician.
Observe what mentioned in the section “Safety
devices”.
Rotating the main switch
(2), the motor hums but
does not start.
e electrical system and/or the
extension are not suitable.
Observe what mentioned in the section “Checks
and connection to mains electricity supply”.
e water cleaner does not
supply hot water.
e Diesel in the tank is below the
minimum level.
e Diesel lter is clogged.
Add Diesel
Observe what mentioned in the section “Special
maintenance”.

Содержание