Aten VK1100A [202/378] Advanced functions

Aten VK1200 [202/378] Advanced functions
ATEN Control System User Manual
176
Advanced Functions
Use advanced options for button/slider actions that involve a series of actions
(Macro), actions that the involve page redirect (Link), or actions that involve
change or update of device settings of multiple objects (Set Variable).
Note: Associate Set Flag, Condition, Change Button State, or Change
Label commands with device commands in the Commands list by
dragging and dropping them into a tree view list, which allows them to
initiate together (see Applications of Advanced Functions, page 178).
Macro sends multiple commands to one or more devices. Select to add a
macro command from the Function list. To create a macro, add multiple
device actions to the Commands list, then click the Save as Macro
icon or access the function by clicking the Library icon (page 98).
Link – makes the button into a link that directs you to a Viewer page.
Select to add a page link from the Function list. Double-click the page link
in the Commands list to select a different page link.
Set Variable creates a variable to represent a device setting (e.g. speaker
volume) that can be used by two or more control objects (e.g. slider bar or
buttons) in the Viewer. This function is used when you have more than one
Viewer objects controlling the same device.
Note: To complete this setting, go to Properties of the control objects and
configure the Set Sync Conditions setting.
Set Flag – sets a flag value to represent the new device status when a
command changes a device setting. Set Flags are added to the Commands
list after device commands to change the Flag (device status).
Condition adds one or more conditions that must be met for commands
to initiate. The conditions can be based on a Variable or a feedback value
(setting value sent from a managed device).
Variable conditions– Use Variable conditions for the controller to carry
out actions (commands) when the specified Variable meets the specified
conditions. Use Variable If, Variable Else If, and/or Variable Else to
fully cover all scenarios in your application. For example, if you want a
display a warning message on the Viewer when the volume of a speaker is
at its maximum (10 dB), you will need to: (a) Set up a Variable for the
speaker volume; (b) Select a Variable If condition; (c) Double-click the
condition to set the Variable value to 10; (d) Drag a Change Label
command and nest it under the condition you selected in step (a); (e)

Содержание