Aten VS481C [25/38] Vs481c user manual

Aten VS481C [25/38] Vs481c user manual
VS481C User Manual
15
RS-232 Commands
Task RS-232 Command Description
Switch the source
Switch the display to a
specific source
sw i<source_number> For example, to switch to source 1, type
sw i01 or sw
Turn on the output port sw on -
Turn off the output port sw off -
Change the switch mode
Enable the next mode
(Default)
swmode next The VS481C switches to the next port
that has a new source device connected
to it.
Enable the priority mode swmode i<source_number>
priority
The VS481C switches to and only
displays the source from a user-defined
port as soon as a source is detected
from the port. For example, to prioritize
port 1, type swmode i01 priority or
swmode priority
Disable the switch mode swmode off Disable the switch mode and the
VS481C does not switch ports
automatically.
Enable the POD mode swmode pod on The Power-on Detection (POD) mode
allows the VS481C to automatically
switch to the next port with a powered-
on source device when the currently
connected source device is powered off.
The POD mode works independently of
the other switch modes.
Disable the POD mode swmode pod off
Other
Read (display) the
VS481C’s settings
read -
Note: Separate each command string with a space.

Содержание

Скачать