SNR S2989G-48TX-POE [116/553] Ddm configuration task list

Превью страниц Страница 116 / 553
SNR S2989G-48TX-POE [116/553] Ddm configuration task list
2-52
S2989G-24TX Operation Manual Chapter 2 Layer 2 services
Configuration
is able to know the abnormity information and renew the monitoring.
2.12.2
DDM Configuration Task List
DDM configuration task list:
1. Show the real-time monitoring information of the transceiver
2. Configure the alarm or warning thresholds of each parameter for the transceiver
3. Configure the state of the transceiver monitoring
1 Configure the interval of the transceiver monitoring
2 Configure the enable state of the transceiver monitoring
3 Show the information of the transceiver monitoring
4 Clear the information of the transceiver monitoring
1. Show the real-time monitoring information of the transceiver
Command
Explanation
User mode, admin mode and global mode
show transceiver [interface ethernet
<interface-list>][detail]
Show the monitoring of the
transceiver.
2. Configure the alarm or warning thresholds of each parameter for the transceiver
Command
Explanation
Port mode
transceiver threshold {default |
{temperature | voltage | bias | rx-power | tx-
power} {high-alarm | low-alarm | high-warn |
low-warn} {<value> | default}}
Set the threshold defined by the
user.
3. Configure the state of the transceiver monitoring
(1) Configure the interval of the transceiver monitoring
Command
Explanation
Global mode
transceiver-monitoring interval <minutes>
no transceiver-monitoring interval
Set the interval of the transceiver
monitor. The no command sets the
interval to be the default interval of
15 minutes.
2 Configure the enable state of the transceiver monitoring