2-51
S2989G-24TX Operation Manual Chapter 2 Layer 2 services
Configuration
make the falling of the module capability that result in the transmission error.
Environment is not compatible with the module are as below:
1 Voltage exceeds the set range
2 Rx power is overload or is under the sensitivity of the transceiver
3 Temperature exceeds the range of the running temperature
2.12.1.2 DDM Function
DDM descriptions are shown in the following:
1. Show the monitoring information of the transceiver
Administrator is able to know the current working state of the transceiver and find
some potential problems through checking the real-time parameters (including TX power,
RX power, Temperature, Voltage, Bias current) and querying the monitoring information
(such as warning, alarm, real-time state and threshold, and so on). Besides, checking the
fault information of the fiber module helps administrator to fast locate the link fault and
saves the restored time.
2. Threshold defined by the user
For real-time parameters (TX power, RX power, Temperature, Voltage, Bias current),
there are fixed thresholds. Because the user’s environments are difference, the users is
able to define the threshold (including high alarm, low alarm, high warn, low warn) to
flexibly monitor the working state of the transceiver and find the fault directly.
The thresholds configured by the user and the manufacturer can be shown at the
same time. When the threshold defined by the user is irrational, it will prompt the user and
automatically process alarm or warning according to the default threshold. (the user is
able to restore all thresholds to the default thresholds or restore a threshold to the default
threshold)
Threshold rationality: high/low warn should be between high alarm and low alarm and
high threshold should be higher than low threshold, namely, high alarm>= high warn>=
low warn>= low alarm.
For fiber module, verification mode of the receiving power includes inner verification
and outer verification which are decided by the manufacturer. Besides the verification
mode of the real-time parameters and the default thresholds are same.
3. Transceiver monitoring
Besides checking the real-time working state of the transceiver, the user needs to
monitor the detailed status, such as the former abnormity time and the abnormity type.
Transceiver monitoring helps the user to find the former abnormity status through
checking the log and query the last abnormity status through executing the commands.
When the user finds the abnormity information of the fiber module, the fiber module
information may be remonitored after processing the abnormity information, here, the user