SNR S2989G-48TX [509/553] Vsf troubleshooting
S2989G-24TX Operation Manual
Chapter 10 Virtualization Configuration
10-14
Switch(config-if-vlan3000)#vsf mad ip add 192.168.1.2 255.255.255.0 member 1
Notice: In this time, the whole vsf is a device, so BFD MAD configuration is equivalent
to conduct on one device.
10.1.4
VSF Troubleshooting
For VSF, under the configuration and usage, the command may not be
workable, please pay attention to the following items:
Whether it is at the operation mode, because some of the commands can only
be configured at VSF operation mode, but some of them can operation at both
VSF and independent operation mode.
Under the failure of VSF during the VSF processes, or appear any abnormity, please
pay attention to the following thing:
First, need to check whether physical connection is correct. Right now, the group
VSF machine can only support million-mega port or logic port colligate. Please
check whether the colligate port is the million-mega port.
Whether the Vsf member id is clash, if the member ids are clashing, the facilities
cannot form vsf.
Whether the Vsf domain numbers are same. Only the vsf domain numbers are
identical, the facilities can form the vsf.
To see whether the logical port has any physical connection, for example, double
speed, bandwidth restriction, safety authentication, ACL etc configuration.
Under the VSF operation mode to undergo configuration, please pay attention to the
following things:
During the VSF operation mode, VSF related configuration can be done on the
each member separately. However, the configuration done on the members
cannot be saved independently. It cans still excute the write function on the vsf
master. All the membes’ personal configuration that is related to vsf will be save
in the main computer’s vsf.cfg.
Under the VSF operation mode, some of the commands such as VSF domain
number, priority of member, member id etc can still be configured or amended.
After the configuration, the show run displays as the latest value, it can only be
effective as you restart the computer after saving.
Under the VSF operation mode, the active mode must be used for port group for
ensuring the fault convergence time.
For LACP MAD, under the configuration and usage, if there are problems,
please pay attention to the following items:
When creating the aggregation group, the aggregation of the device which is
detected and the middle device must be identical.
The ports of the device which is detected and the middle device cannot be added
into the aggregation with on mode for LACP MAD, one should be active method